![Dea 212E Operating Instructions And Warnings Download Page 13](http://html.mh-extra.com/html/dea/212e/212e_operating-instructions-and-warnings_2460972013.webp)
11
5
Learning work times with 2-motor operations
Commands
Function
LED status
1.
Run the gear motor release operation, manually move the door to the fully closed position and
lock the gear motor again.
2.
Press SEL repeatedly until the “PROG” LED turns on.
3.
Press and hold down the SET key until the “PROG” LED starts to quickly flash indicating that
work time learning has started.
4.
Release the SET key.
5.
Press START: motor 1 starts opening.
6.
Wait for the required door offset time.
7.
Press START: motor 2 starts opening.
8.
When motor 1 reaches limit stop, press START: motor 1 stops.
9.
When motor 2 reaches limit stop, press START: motor 2 stops.
10.
Press START: automatic closing time countdown starts.
WARNING:
To disable automatic closing, hold down until motor 2 closing starts and skip di-
rectly to point 13.
11.
Wait for the required automatic closing time.
12.
Press START: motor 2 starts closing.
13.
Wait for the required door offset time.
14.
Press START: motor 1 starts closing.
15.
Several sec. after reaching the relevant limit stop, both motors automatically
stop. The “PROG” LED turns back on, work time learning has completed.
16.
At this point, press SEL to select any other programming function or exit programming (all LED
off).
6
Program mode selection (reverse or step by step)
Commands
Function
LED status
1.
Press SEL repeatedly until the “MODE” LED turns on.
2.
Press SET and immediately release it: the “MODE” LED starts to flash indicating the currently
selected program:
- slow flashing = step by step;
- fast flashing = reverse.
3.
Press SEL to change the operating program type.
4.
Press SET and immediately release it: the “MODE” LED turns back on (new program saved).
5.
At this point, press SEL to select any other programming function or exit programming (all LED
off).
Once unit programming is completed, press SEL repeatedly until all LED turn off. At this point the unit is ready to receive controls.