EMERGENCY SITUATIONS
1. The counter does not start or switches off.
Check whether there is an electrical blackout in progress;
Check that the main wall switch is on.
If the electrical interruption does not depend on the above-mentioned reasons, immediately contact
the closest service centre and fully empty the counter, placing the removed products in cold rooms or
in other equipment capable of preserving them.
2. The counter temperature is too low.
Check that the counter is not loaded beyond the recommended level and that the air vents are
not obstructed;
Start a forced defrost and clean the counter (following safety measures) to then resume standard
operation;
Make sure that the counter is not near heat sources and/or air draughts which could hinder
proper operation;
Should malfunctioning persist, immediately contact the closest service centre.
3. The counter makes too much noise.
Check that the screws and nuts are fastened all the way.
Using a level, check that the counter is level.
Should the noise persist, immediately contact the closest service centre.
4. Gas Leak or Fire.
Should this critical situation occur, move away from the counter. Disconnect the counter from the
main switch and ABSOLUTELY DO NOT USE WATER TO PUT OUT A FIRE, BUT ONLY USE DRY
FIRE EXTINGUISHERS and activate the emergency procedures.
5. Other particular situations.
Metal parts must be handled with care to avoid possible and not unlikely abrasions and/or cuts as
well as possible crushing.
Removing the bottom surfaces exposes the evaporator and motor fans with the ensuing danger
that this could cause.
Should an accident damage one or more glass doors, pay attention not to touch live wires which
could easily be reached
.