background image

Linear Movement Apparatus // 

User´s manual

Linear Movement Apparatus // 

User´s manual

20

19

WARNING

In case the product is not working 

pr

operly

, is damaged or needs 

maintenance, please contact us. We 

will gladly help y

ou to solve an

y issue.

Avoid using sharp objects 

with the product.

Protect the product from 

rain and water.

Alwa

y

s ensure the proper 

power input.

Do not try to fix or 

disassemble this product 

by y

ourself.

PROCEDURE

// GENERAL RECOMMENDATIONS

Before you plug in the equipment be sure 

that the electric supply of your country or 

region is the right one to operate the 

equipment. Be aware that the unit can 

operated at 110V or 220V (50 or 60Hz).

Summary of Contents for 31202A

Page 1: ...Model 31202A LINEAR MOVEMENT APPARATUS USER S MANUAL User s manual version 2 ...

Page 2: ...will find this equipment most reliable and accurate exceeding your expectations Before using this device we strongly recommend that you carefully read the user manual There you will find all related information for correct handling and usage of this product We hope that you enjoy using this equipment as much as we did creating it De la Rosa Research Team ...

Page 3: ...6 Details 8 Specifica on 10 Applica ons 12 Features Pag 18 Procedure Pag Pag Pag Pag INDEX ...

Page 4: ...superior switch located in a cube a without external clues To evaluat dimensions an LCD readout display the switch in the cube is mov an be used for motor learning tasks This device has been used tudies and motor skill evalua on ts of an op cal encoder that ch displacement The subject moves t a specified distance or speed e the subject s ability to judge these s the distance and me in which ed This...

Page 5: ...near Movement Apparatus User s manual 8 7 Light discrimination aparatus User manual SPECIFICATIONS Line Voltage 110 220 V AC 50 60 Hz Current 10 Amps Supplied with User Guide Accuracy 1mm 0 5mm Heigh 10 4 Wide 5 3 Depth 46 8 Weight 11 kg Aprox ...

Page 6: ...manual Linear Movement Apparatus User s manual 10 9 Linear Movement Apparatus User s man 10 The syst basic for avia APPLICATIONS em measures me es ma on speed and distance on personnel professional drivers and high performance athletes ...

Page 7: ...Linear Movement Apparatus User s manual Linear Movement Apparatus User s manual 12 11 Light discrimination aparatus User manual FEATURES Recyclable materials ...

Page 8: ... easy carrying BODY Aluminum stainless steel HDPE and acrylic body for sturdy usage High resistance and 100 recyclable polymer base easy to clean PRECISION SWITCH ON SLIDE High rated contact switch for long lasting usage MATERIALS Built from high quality components manufactured in USA Japan Italy and Colombia among others ...

Page 9: ...15 FEATURES POWER SUPPLY vailable for 110 V and 220V countries USB PORT USB port for serial communication the software will be available and supplied at no charge RULE Distance guide rule LCD CONTROL LCD and key pad controlEasy to read LCD displayAllows distance and time measurements ...

Page 10: ...Linear Movement Apparatus User s manual Linear Movement Apparatus User s manual 18 17 PROCEDURE General recommendations Initial settings Operating ...

Page 11: ...ve any issue Avoid using sharp objects with the product Protect the product from rain and water Always ensure the proper power input Do not try to fix or disassemble this product by yourself PROCEDURE GENERAL RECOMMENDATIONS Before you plug in the equipment be sure that the electric supply of your country or region is the right one to operate the equipment Be aware that the unit can operated at 110...

Page 12: ... and in a manner that does not see the rule this may only Be seen by the experimenter Place the equipment in a flat surface Leveling the surface is desired for op mal performance Be sure the support points are in contact with the suppor ng surface 1 4 3 Place the LCD control away from the subject to prevent him her to see the informa on displayed EXPERIMENTER ...

Page 13: ...Movement Apparatus body x1 b LCD Control x1 c Serial cable DB25 x 1 d USB cable A B x1 e Power cable Cable AC x 1 PROCEDURE INITIAL SETTINGS WHAT SHOULD BE INCLUDED IN THE PACKAGE c x1 d x1 b x1 Depending on the geographical area you will be given one of these AC cables one per package a x1 e x1 ...

Page 14: ...ale end of the cable should be connected to the LCD control A C c POWER CABLE Connect the A C cable The opposite end should be connected to a 110 220VAC 50 60Hz power outlet USB CABLE USE ONLY IF CONTROL SOFTWARE IS AVAILABLE The smallest end B of the USB cable f should be connected to this port The opposite end of cable A should be This USB cable has two different ends B A ...

Page 15: ...oftware Note that you can choose whether or not to use the software If you don t need to use any function of the software skip these steps and continue to the next page 28 Disk Space 222mb Administrator permission Os Windows 7 8 10 64 bits Minimum ram 2gb Technical requirements SoftSuite2 If you have not downloaded the software and you want to do so enter https delarosaresearch com downloads php p...

Page 16: ...ble check that the AC power Cable is safely and securely plugged to both the main unit and the AC wall outlet Also check that all the cables are set accordingly to the previous steps TURN ON AC POWER CABLE Connect the AC power cable g Please verify that the neither f USB B connector is connected to the equipment or the USB A connector is connected to the PC when you start the equipment ATTENTION ...

Page 17: ...onnector of the provided USB Cable to the main unit then connect the USB A connector to a computer s USB port At this point you must have the SoftSuit2 software installed on your computer considering that you are going to use any of its functions If you do not need to use any software functions skip this step and continue with page 33 ...

Page 18: ...seconds 10 tenths 1 second 1 millimeter T point indica ng direc on Distance is given in tenths of millimeters 1 10 Left Down Right Start Stop Reset Up T represents the TIME Here is the me elapsed since the subject takes the precision switch on slide moves it and releases it TS means TEST and refers to the number of tests to be performed The Test is counted from 0 to 9 S means SPEED and refers the ...

Page 19: ...ans that it is ready to move it and perform the test The point where it starts will be taken by the system as the zero point 0 and the movement made from this point will be the one taken by the test SELECTING TEST A total of 10 tests trials can be selected using the UP and DOWN keys Selected test will be presented now Up Down You will see a blue light while the precision switch on slide is being s...

Page 20: ...ll be able to start a new test repeat the current test or finish the experiment Use a spreadsheet on your computer or a sheet of paper and write down the results obtained in the test You can also make use of the software that will allow you to perform this process automatically and export the results to a spreadsheet You can select another test within ten 10 possible and perform new tests These wil...

Page 21: ... this button to navigate between workspaces 5 Left Option not available 6 Right Option not available 7 HOW TO LAUNCH VIRTUAL LCD CONTROL Introduction VIRTUAL LCD CONTROL START To launch the virtual lcd control select the button located in the left bar menu and then wait a few seconds VIRTUAL LCD CONTROL CONTROL PANEL Then read the information displayed and enter the LCD Control panel LCD CONTROL P...

Page 22: ... the results obtained in the test During the test you will see a window that indicates when the test is in progress Once the subject releases the sensor the results will be displayed VIRTUAL LCD CONTROL DO THE TEST Press the button 2 Start Stop to start a test follow the instructions shown the test will start when the system prompts you to hold the sensor If you need to reread the steps to perform...

Page 23: ...43 VIRTUAL LCD CONTROL CLOSE To close the virtual lcd control press the upper right button VIRTUAL LCD CONTROL NEW TEST To select another workspace use the 3 Up and 4 Down buttons There are 10 workspaces if you need to perform more than 10 tests you must overwrite a previous workspace ...

Page 24: ...nd of this user guide This was all the basic information you need for using the LINEAR MOVEMENT APPARATUS but this is just the beginning of the fun If there is something that is not clear to you or if you have any questions please feel free to contact us at any time We will be very happy to hear from you support delarosaresearch com 57 1 6151702 57 3003642343 Cll 147 A 48 08 Bogotá Colombia De la ...