background image

     

 

 

1

 / 

11

 

 

WWW.DDTOP.COM 

 

 

UTK 

DISPLACER LEVEL SWITCH 
 

Operation Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

TK
-

DT
-

JS

-

10
1

2

-

20
18

(A)

 

Summary of Contents for UTK

Page 1: ...1 11 WWW DDTOP COM UTK DISPLACER LEVEL SWITCH Operation Manual UTK DT JS 1012 2018 A...

Page 2: ...ut prior notice Quality Assurance Dandong Top Electronics Instrument Group Co Ltd guarantees that all glass plate level gauge have no defects in materials and manufacturing processes within one year f...

Page 3: ...3 Technical Characteristics 7 3 1 Main Performance 7 3 2 Main Parameters 7 4 Dimensional Outline Drawing Figure 2 7 5 Unpacking and Inspection 8 5 1 Unpacking Inspection Notice 8 Figure 4 Sample Name...

Page 4: ...ment in intrinsically safe or non flammable site operating procedures 1 2 Process leaks can cause serious injury or death Care should be taken to lift the transmitter If the process seal is damaged th...

Page 5: ...0 Spring assembly 11 Displacer 12 Wire rope 2 2 Operating Principle 2 21 Classification of Displacer Level Switch The Displacer Level Switch is divided into ball float type and displacer type based on...

Page 6: ...an be controlled and given an alarm 2 1 3 Displacer Type Operating Principle With the displacer as the sensing element the displacer hangs on a spring through the suspension rod When the level is rais...

Page 7: ...rmance 3 1 1 Has passed the national explosion proof certification certification mark Intrinsically safe Ex ia CT1 T5 T6 Explosion isolation Ex d CT1 T5 T6 3 1 2 Product Standard Q AMM 004 Displacer L...

Page 8: ...Figure 4 is consistent with the information in the supply list 5 1 2 Check the quantity and material of each part against the packing list 5 1 3 Check the appearance of the instrument for defects dama...

Page 9: ...ation for Commissioning 7 1 1 Debugging tools Multimeter 7 2 Electrical Wiring 7 2 1 Wiring Cable Preparation The wiring cable shall be outer diameter 10mm five core rubber sleeve soft wire or rubber...

Page 10: ...with water If medium water it can t be debugged with water It can only be debugged with actual measuring medium 4 For medium water When calibrating with water the alarm position will be lower than the...

Page 11: ...ctual alarm position and specification 1 Process condition is not consistent with design condition The actual density or alarm setting value is inconsistent with the design value 2 On site heat tracin...

Reviews: