 Operating Principle-Figure 2

 

Integral orifice flow meter and standard orifice plate are based on the principle of fluid continuity 
and Bernoulli's equation of conservation of energy, putting a piece of integral orifice plate into a full 
tube of medium in the process pipeline, when the fluid flows through the integral orifice plate flow 
meter, the flow beam will be in the flow element to form a local contraction, thereby increasing the 
flow rate, low static pressure, so the flow element will produce a pressure drop before and after the 
pressure drop, that is, the pressure difference, the greater the flow of the medium, the greater the 
pressure difference generated before and after the flow element, through the differential pressure 
transmitter  can  output  and  the  measured  fluid  flow  value  as  a  square  relationship  between  the 
standard signal, can be converted into flow value. 

 

Basic Calculation Formula: 

或 

                           

  or 

                         

C-- Outflow coefficient dimensionless 
ε-- Coefficient of expansion 
β-- Throttle diameter ratio 
d—mm    Throttle orifice diameter    mm 
ΔP--Pa    Differential pressure    Pa 
ρ-- kg/m

  Density of measured medium    kg/m3 

 

2.3 Package 

Please send packaging waste to a special recycling agency. 

2.4 Lifting Transportation 

Please use qualified lifting equipment and lifting straps, and pay attention to safety. 

2.5 Storage 

Storage temperature -20℃~40℃; storage humidity  ≤20%. 

3 Main Executive Standard 

Comply with GB/T2624-2006, ISO5167-2003, BS1042-1992 and other standards. 

4 Main Features 

4.1 Transmitter and flow element integrated installation, saving installation and maintenance work. 

Summary of Contents for LGNC

Page 1: ...1 8 WWW DDTOP COM LGNC INTEGRAL ORIFICE FLOW METER Operation Manual LGNC DT JS 1029 2018 A...

Page 2: ...rior notice Quality Assurance Dandong Top Electronics Instrument Group Co Ltd guarantees that all products will be free from defects in materials and manufacturing processes within one year from the d...

Page 3: ...m and 10 times the pipe diameter downstream which achieves a good rectification effect and reduces uncertainty 6 4 3 High precision after the actual flow calibration of integral orifice plate flow met...

Page 4: ...or non flammable site operating procedures 1 2 Process leaks can cause serious injury or death If the process seal is damaged the medium may leak at the connection 1 3 Failure to follow the safety in...

Page 5: ...d before and after the flow element through the differential pressure transmitter can output and the measured fluid flow value as a square relationship between the standard signal can be converted int...

Page 6: ...ge points 5 Outline Dimension Diagram Figure 2 The dimensions of D and L in the picture are subject to the actual product 2 Figure 2 6 Unpacking and Inspection 6 1 Precautions for Unpacking Inspection...

Page 7: ...anges slowly 8 5 Before the fluid flows through the flow element its stream must be parallel to the axis of the pipeline and there must be no rotating flow 8 6 The standard flow element is not suitabl...

Page 8: ...ned on Turn on power supply 2 Stop valve is not opened Open the stop valve 3 Differential pressure transmitter failure Check differential pressure transmitter Medium leakage at the flow element 1 Insu...