3
1.4 after Servicing
After servicing the unit, whether at a site or service center, check the following:
MAKE CERTAIN THERE ARE NO LEAKS IN THE DRAIN OR WATER LINES. Check the water line, water valve, drain valve, and drain
•
tubing for leaks.
Make certain the Ice Maker functions properly by observing ice production and ice harvest cycles. Check for hollow ice slabs
•
or ice slabs that will not release.
Make certain the bin thermostat will turn the unit off. The best way to check this is to let the Ice Maker bin fill with ice. How-
•
ever, if time is restricted then use several ice cubes and place them on the bin thermostat’s capillary tube sleeve located on
the side of the ice bin. The unit should shut down within a few minutes. After removing the ice, the unit should start at least
five minutes later.
1.5 BaSic refrigeration toolS
The following list contains SOME of the tools required for basic refrigeration repairs:
Hoses with R-134a couplers (must meet standards for handling R-134a refrigerant)
1.
Approved and certified recovery system for R-134a
2.
Manifold gage set for R-134a
3.
Charging cylinder with R-134a
4.
Weight scale (preferably in ounces to the nearest tenth of an ounce)
5.
Access valves
6.
Small and large tubing cutter
7.
Brazing torch
8.
Swaging tools
9.
Multimeter
10.
Leak detection equipment for detection of R-134a
11.
Standard hand tools (assorted Phillips and standard screwdrivers, sockets, allen wrenches, adjustable wrenches, etc.)
12.
Rivet gun and assorted rivets
13.
Drill motor and assorted metal drills
14.
Vacuum pump
15.
1.6 inStallation
Unit can be installed freestanding or enclosed. The front of the unit must be unobstructed for proper air circulation and op-
•
eration at all times.
Area should be ventilated with a temperature above 55 degrees F and below 90 degrees F for proper operation.
•
Unit can be installed outdoors and away from the elements of nature. As the unit is rated for outdoor, it has added electrical
•
protection and is UL tested and recognized for outdoor use.
UNIT MUST BE ON A LEVEL SURFACE capable of supporting the loaded weight of the unit.
•
For additional information, refer to the Owner’s Guide supplied with the unit.
•
1.7 electrical reqUirementS
Warning
ELECTRICAL SHOCK HAZARD
Failure to follow these requirements could result in personal injury,
electrical shock, or fire.
115 VAC, 60 Hz., single phase power is needed
•
Use an outlet with a 15 amp circuit. A ground fault circuit interrupter (GFI) electrical receptacle is to be used to supply electri-
•
cal power to the Ice Maker.
INTrOduCTION
Summary of Contents for RF151
Page 1: ...1 ICE MAker Service manual Models RF15I ...
Page 2: ......
Page 28: ...26 Figure 7 1 Ice Maker Wiring Diagram WIRING ...
Page 40: ...38 NOTES ...
Page 41: ...39 NOTES ...
Page 42: ...40 NOTES ...
Page 43: ......