dCS Delius
User Manual
Manual for Software Issue 2.3x
dCS
Ltd
September 2004
Manual filename: Delius Manual v2.3x.doc
Page 41
email: [email protected]
English version
web-site: www.dcsltd.co.uk
REC
Digital Output
The
REC
output buffers and loops through the selected single wire input data
with sample rates up to 96kS/s. The data format is the same as the selected
input (i.e. AES3 or IEC60958), the electrical format is SPDIF. It may be
connected to a digital recorder or another DAC. Use with 75 ohm co-axial
cables designed for digital audio or RF use.
IMPORTANT!
This output is intended for use with Single AES, RCA, BNC, Toslink or ST
inputs
ONLY
. If the selected input is in any other format, the
REC
output
will carry either the left channel data or full scale noise.
IMPORTANT!
If the selected input is SPDIF and the Copy Prohibit flag in the source data is
set, the
REC
output will be the same and you will not be able to record the
data.
1394
Interface
Units fitted with an IEEE
1394
multi-channel interface feature two 6-way 1394
connectors. The active source is selected by the
Input
button, see page
In this release, the unit accepts DSD data at 2.822MS/s from either
1394
connector. For correct operation, the source must generate a 44.1kHz
wordclock (or be locked to a master clock running at 44.1kHz) and this must be
connected to
Delius’
Wordclock In
connector. We recommend using the 1.8
metre long, 6-way IEEE 1394 cable assembly and the BNC cable assembly
provided. See the “IEEE 1394 Overview” section on page
for more
information.
Wordclock
Digital Input / Output
The
Wordclock In
put accepts a Wordclock at sample rates up to 96kS/s. It
allows
Delius
and your source equipment (e.g. CD or DVD player) to be
synchronised to a master clock. This arrangement helps reduce jitter, which can
degrade the audio output. See the
MS
menu page on page
for details.
The
Wordclock
Out
put is intended to synchronise other equipment to
Delius
. In
Master mode, the unit outputs a 44.1kHz master clock for other equipment to
lock to. In Slave or Sync modes, this output is disabled. See the
MS
menu page
starting on page
for more details.
There is no data on the
Wordclock
interface. Use with 75 ohm co-axial cables
designed for digital audio or RF use.
SUC
The Software
Upgrade Connector is intended to be used by
dCS
service agents
to load new software into
Delius
.
IMPORTANT!
Do not connect any other equipment to the SUC connector as this may
damage both
Delius
and the equipment so connected. Do not operate
Delius
with a PC connected. Failure to observe this warning will void the unit’s
warranty, and may cause unpleasant effects in your system.