13
INSTALLER FINAL CHECKLIST:
GRILL BURNER FLAME HEIGHT:
To access the grill burner air shutters first remove the valve panel by removing it the same way as
described on page 12, section “Before Testing”. With a screw driver, loosen the lock-screw on the face
of the air shutter. Light the burner and adjust according to the directions below. Access for the side
burner air shutters is through the top after removing the top burner grate and aeration pan assembly
(See Fig. 08).
❏
Specified clearances main-
tained to combustibles.
❏
Nylon straps removed from
burners.
❏
All internal packaging
removed.
❏
Knobs turn freely, bezels
centered.
❏
Each burner lights satisfac-
torily, individually or with
adjacent burner lit.
❏
Air shutters adjusted.
❏
Adjustable low setting satis-
factory.
❏
Drip pan in place properly
and sliding freely.
❏
Pressure regulator
connected and set for 4.0"
W.C. Natural, 11.2" W.C. LP
gas.
❏
Manual shut-off valve
installed and accessible.
❏
Unit tested and free of
leaks.
❏
User informed of gas supply
shut-off valve location.
❏
All radiants are assembled
(see page 15) and put in
place.
n
PLEASE LEAVE THESE
INSTRUCTIONS WITH THE
USER.
n
USER, PLEASE RETAIN
THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
1-1/2"
3/8"
Aeration Pan
Lighter
Ports
Burner
Hanger
Air
Shutters
Flash
Tubes
Venturi
Tube
Igniter
FIG. 07 Burner Flame Height
FIG.8 Power Burner Air Shutters
INSTALLER CHECKLIST/BURNER ADJUSTMENTS