3. Configuration
3.1. Factory setting parameters
:
Parameter
Default setting
Explanation
Username
admin
Password
admin
Please remember the password
after change
LAN Network Setting
DHCP
PC Network Setting
Static IP
192.168.8.1
LAN IP
*00(Chinese)
*01(English)
Press “*00” or “*01” get IP address
LAN IP Setting
*03
Such as *03192*168*1*2#
Restore factory
*11983185922
After input password and hear
“Toot”, then success, you just to
pull power and restart the
Gateway.
3.2. Log on to the Gateway
3.2.1. Get IP
A) Make sure that there is DHCP sever: In accordance with connection diagram
2-3
,
connect the Gateway and open power , see if the RUN light flash or not.
About the RUN light quick flashes 10 seconds, put up the telephone and press
*00, telephone will report IP address in Chinese; Press *01, then will report in
English.
B) Without DHCP sever in the Network: Put up the telephone and press *03+IP
address, such as “*03192*168*1*2#”
,
indicates that IP temporary address is
192.168.1.2. If you want to know how setting is successful, just to press *00 or
*01 and hear the IP again. Notice that the temporary IP is not the same as the
PC-segment and not conflict with other Network setting. The same
PC-segment means the first three sections the number of IP must consistent,
such as 192.168.8.1 and 192.168.8.5 are the same segment, 192.168.1.3 and
192.168.2.4 are not.
C) The default IP address and mask of the PC port are 192.168.8.1 and
255.255.255.0 respectively.
Connect the computer with the PC port of the gateway through the IP address
of the PC port, and set the IP of the computer to dynamic IP or fixed IP as
192.168.8.xxx and the default gateway as 192.168.8.1.