DVB-T/T2 terrestrial receiver
MERlin
Using the Web Page
2013 dB Broadcast Ltd
21
Version 1.2
DVB-T Configuration
Tuning Configuration
For receiver setup see
Tuning and checking the receiver
in the Installation chapter.
Station Identity
This has been moved to the Device Configuration tab.
Alarm Configuration
There are two relay alarms, critical alarm and non critical alarm available on the rear connector.
The critical alarm is dedicated to microprocessor failure.
The DVB-T non-critical alarm is programmed on the DVB-T Configuration tab.
RF Input Level
Sets minimum and maximum RF input level, enter value and press Set. Tick box enables alarm.
MER
Sets minimum MER value, enter value and press Set. Tick box enables alarm.
Frequency Error
Sets lower and upper Frequency error, enter value and press Set. Tick box enables alarm.