DB Audio DS10 Manual Download Page 7

 

Power supply

Mains connector

powerCON

®

Rated mains voltage

100 to 240 V, 50 – 60 Hz

Overvoltage protection

Up to 400 V AC

Power consumption

10 W (max)

Digital inputs

Connectors

3 pin XLR female, AES3

Pin assignment 

1 = GND, 2 = AES Signal, 3 = AES Signal

Input impedance

110 ohms

Sampling

32 – 192 kHz

Synchronization

Sample Rate Converter (SRC)

Digital outputs

Connectors

3 pin XLR male, AES3

Pin assignment 

1 = GND, 2 = AES Signal, 3 = AES Signal

Output impedance

110 ohms

Sampling

48/ 96 kHz

Synchronization

Dante network

Network

Connectors

etherCON

®

built-in 5-port Ethernet switch

100/1000 Mbit

Controls and indicators

BYPASS/NETWORK

Toggle switch

Switch port modes/Audio loss

RGB LEDs

SYNC ERROR

LED indicator red

SUBSCRIBED (RX Subscription)

LED indicator green

Dimensions and weight

Height x width x depth

1 RU x 19" x 232 mm

1 RU x 19" x 9.1"

Weight

3.75 kg / 8.26 lb

2. Technical specifications

 

d&b DS10 Manual 1.5 en

7

Summary of Contents for DS10

Page 1: ...D DS10 Manual 1 5 en...

Page 2: ...website for the latest version of this manual When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this manual E...

Page 3: ...ower cord from being walked upon or pinched particularly at the plugs and the point where it exits from the apparatus 9 The unit is intended for use in a 19 rack Follow the mounting instructions When...

Page 4: ...D 12 3 5 Rear panel 13 3 5 1 ETH 5 MODE ETH 3 13 3 5 2 DIGITAL OUT 5 16 13 3 6 Meta data 13 4 Rack connections 14 4 1 Use with d b Touring rack I O panel 14 5 Application examples 15 5 1 Redundant 16...

Page 5: ...lighting control apparatus for professional use for the environments E1 residential E2 business and commercial E3 outdoor use in urban areas and E4 outdoor use in rural areas Acoustic interference and...

Page 6: ...f the mains distributor 3 2 E7500 024 AES EBU XLR cable Used to connect the digital outputs 1 2 and 3 4 to the digital inputs D1 2 and D3 4 of the I O panel 4 1 K6018 025 CAT5e patch cable Used to con...

Page 7: ...nectors 3 pin XLR male AES3 Pin assignment 1 GND 2 AES Signal 3 AES Signal Output impedance 110 ohms Sampling 48 96 kHz Synchronization Dante network Network Connectors etherCON built in 5 port Ethern...

Page 8: ...cated indicators for Ethernet link Activity indicator Ethernet Gigabit indicator Switch port mode indicator Refer to Chapter 3 4 4 ETH1 ETH4 on page 11 5 6 SYNC ERROR and SUBSCRIBED indicators Refer t...

Page 9: ...supplies with protective earth only If there is any sign of obvious damage to the power cord and or mains connector do not use the power cord and replace it before further use Please ensure the mains...

Page 10: ...ce is working When switching from NETWORK to BYPASS the output channels are routed from the DS10 digital inputs as described above and all devices on the Dante network that were receiving audio from t...

Page 11: ...ndary Primary Secondary Primary Redundant VLAN Primary Secondary VLAN VLAN VLAN Primary with Multicast Filter This port is connected to the Primary network but the Multicast audio is filtered out The...

Page 12: ...twork troubleshooting For example if the Secondary link of the mixing console is interrupted the switch mode indicators of the ports configured as Secondary will flash 3 4 5 SYNC ERROR SUBSCRIBED SYNC...

Page 13: ...provided on the rear panel to allow further AES channels to be used if more than four AES channels are required 3 6 Meta data The DS10 sends meta data Dante channel labels cabling information via the...

Page 14: ...of the Ethernet ports on the I O panel to the DS10 Otherwise an Ethernet ring is built causing a packet storm Network no longer accessible 4 On the rear connect the power cord 2 powerCON powerCON to...

Page 15: ...for illustration purposes only and do not aim to cover every possible application nor describe comprehensive PA Systems It is not possible to provide an exhaustive list of all possible applications a...

Page 16: ...works can be built If one fails audio will continue to pass without any kind of interruption on the other network Note For remote control applicable d b amplifiers will normally be connected to the Pr...

Page 17: ...d as a break in box with a maximum of four AES3 Input channels per DS10 additional DS10 can be used if more channels are required at the FoH A star wired configuration is shown below but the same prin...

Page 18: ...ly routes multicast audio to the Dante nodes that have requested it and not to the port to which the Wireless Access Point is attached Note Some switches provide the option to filter all multicast tra...

Page 19: ...ut allows multicast control to pass through This enables wireless control without the need for external switches with IGMP Snooping Switch mode configuration The DS10 in the left and central Touring r...

Page 20: ...b can result in the DS10 becoming unusable Firmware update files are provided by d b at www dbaudio com We recommend you to regularly check the d b website for the latest firmware version together wi...

Page 21: ...o E4 DIN EN 55103 2 1996 classes E1 to E4 d b audiotechnik GmbH of Backnang accepts responsibility for this declaration Backnang 2015 01 15 Frank Bothe Head of R D d b audiotechnik GmbH 7 2 WEEE Decla...

Page 22: ...D2027 EN 01 01 2016 d b audiotechnik GmbH www dbaudio com...

Reviews: