Technical features:

• 6-digit red display (optional: green, orange, blue)
• minimal installation depth: 70 mm excluding plug-in terminal
• programming interlock via access code
• protection class IP65 (front side)
• plug-in terminal

User manual M2

Profibus DP

96x48

M2_1B9GB.pdf   updated: 08.03.2012

Summary of Contents for M2

Page 1: ... optional green orange blue minimal installation depth 70 mm excluding plug in terminal programming interlock via access code protection class IP65 front side plug in terminal User manual M2 Profibus DP 96x48 M2_1B9GB pdf updated 08 03 2012 ...

Page 2: ...nit Installation depth 89 mm incl plug in terminal 2 Version B B Housing size B96xH48xD70 mm 1 Setpoints 0 no setpoints Display type binary B Protection class 1 without keypad Display colour operation on the back Blue B 7 IP65 plug in terminal Green G Red R Supply voltage Yellow Y 4 115 VAC 5 230 VAC Number of digits 6 10 30 VDC galv insulated 6 digit 6 Measuring input Digit height 0 none 14 mm B ...

Page 3: ... 7 5 2 Operating mode 2 7 5 3 Operating mode 3 8 5 4 Operating mode 4 8 5 5 Operating mode 5 9 5 6 Explanations to panel parameters 10 5 7 Explanations to the position after decimal point 10 5 8 Explanations to the mode 11 5 8 1 Modus 0 11 5 8 1 Modus 1 11 6 Error indications 12 7 Factory settings 13 7 1 Synoptical table 13 7 2 Reset to factory settings 13 8 Technical data 14 9 Safety advice 15 ...

Page 4: ...9 0 1 After removing the fixing elements insert the device 2 Check the seal to make sure it fits securely 3 Click the fixing elements back into place and tighten the clamping screws by hand Then use a screwdriver to tighten them another half a turn CAUTION The torque should not exceed 0 1 Nm The dimension symbols can be exchanged before installation via a channel on the side ...

Page 5: ...f the data line require a termination One in the triggering included termination needs to be activated The maximum allowable length of the data line depends on the baudrate an is 1000 m For simplification of the electrical connection the terminals are carried out doubly At the last device of tha bus line the termination can be switched onto the bus line with two bridges ...

Page 6: ...lways signalised by a flashing of the display Settings that are made in the parameterisation level are confirmed with P and thus safed By pressing the O key zero key it leads to a break off of the value input and to a change into the menu level All adjustments are safed automatically by the device and it changes into operating mode if no further key operation is done within the next 10 seconds Ope...

Page 7: ... bevor switching back into operation mode After this the new address will be directly in use Parameterisation level Menu level 4 1 Switching on Once the installation is complete you can start the device by applying the voltage supply Before check once again that all electrical connections are correct Starting sequence For 1 second during the switching on process the segment test 8 8 8 8 8 is displ...

Page 8: ...f of the parametrisation run With the navigation keys one can choose between the deactivated key lock Uloc works setting and the activated key lock Loc Confirm the selection with P After this the display confirms the settings with and automatically switches to operating mode If Loc was selected the keyboard is locked To get back into the menu level press P for 3 seconds in operating mode Now enter...

Page 9: ... 1 0 Position after decimal point signed integer Position after decimal point see 7 7 0x21 0x20 Panel parameter see 7 6 0x21 Function Description Characteristic Byte No 2 Bytes output data 2 1 Byte output data 1 2 Bytes output data 0 5 2 Operating mode 2 Display value of 16 bit signed integer values 32768 32767 with brightness control flashing and position after decimal point Configuration data Ou...

Page 10: ...eger Position after decimal point see 7 7 0x23 0x20 Panel parameter see explanations 7 6 0x21 Function Description Characteristic Byte No 4 Bytes output data 4 1 Byte output data 1 2 Bytes output data 0 5 4 Operating mode 4 Display value of 16 bit signed integer value 32768 32767 with brightness control flashing and position after decimal point Configuration data Output data Display value High Wor...

Page 11: ...ect display triggering with brightness control Configuration data Output data With 6 digit displays the 1st and 2nd digit may not be triggered and so on But all 8 digits always need to be assigned 7 Digit 9 6 Digit 8 5 Digit 7 4 Digit 6 3 Digit 5 2 Digit 4 1 Digit left display digit with the highest value 3 Mode see explanations 5 8 2 Panel parameter see explanations 5 6 Function Byte No 8 Digit r...

Page 12: ...ness 11 equates 25 brightness Function Byte Nr Flashing at 8 digt right display digit with highest value 15 0 1 Brightness control not availabe for outdoor displays 5 7 Explanations to position after decimal point 0 Display 1 Display test 7 Reserved 3 6 000 no position after decimal point 001 1 position after decimal point 010 2 positions after decimal point 011 3 positions after decimal point 100...

Page 13: ...Byte No 0 6 ASCII table At all empty fields a space is displayed 70 60 50 40 30 20 10 00 0F 0E 0D 0C 0B 0A 09 08 07 06 05 04 03 02 01 00 HEX 5 8 1 Mode 0 5 8 2 Mode 1 Direct triggering of the segments bit coded all values in hexadecimal notation Example To display the sign with the ASCII code 32H 2 in mode 1 the value 5BH 01H x 02H 40H 10 H 08H needs to be entered in the data field 2 0 H 0 2 H 1 0...

Page 14: ...isplayed which state the operating mode Watchdog in Gateway is invalid Er8 Watchdog overflow Gateway works in an inoperative operating type Er7 Configuration error Profibus master offline Er6 Data exchange error Gateway receives too many data Er5 DATA overflow Gateway checksum of a parameter is faulty Er4 PCHECKSUM error Gateway Profibus error Er3 SPC3 error Communikation error with EEPROM Er2 EEP...

Page 15: ...ollowing procedure should be used Switch off the power supply Press button P Switch on voltage supply and press P button until is shown in the display 7 2 Reset to factory settings default values To return the unit to a defined basic state a reset can be carried out to the default values With reset the default values of the program table are loaded and used for subsequent operation This puts the u...

Page 16: ...010 EN 60664 1 Safety standard Pull up down according to EN50170 Bus termination max 1000 m Wire length 92 0 0 8 x 45 0 0 6 mm Panel cut out 96x48x89 mm BxHxD incl plug in terminal RS485 Interface Autobaud recognition up to 12 MBaud Baud rates Profibus DP Protocol Interface Profibus 6 digit Display Red optional green yellow or blue Segment colour 14 mm Digit height Display Plug in terminal wire cr...

Page 17: ...noid valves etc near the device and suppress any interference with the aid of RC spark extinguishing combinations or free wheeling diodes Keep input output and supply lines separate from one another and do not lay them parallel with each other Position go and return lines next to one another Where possible use twisted pair So you receive best measuring results Screen off and twist sensor lines Do ...

Page 18: ...16 ...

Page 19: ......

Page 20: ...Stand 08 03 2012 M2_1B9GB pdf ...

Reviews: