background image

INS463A-09/20

www.davisandshirtliff.com

Summary of Contents for OSMOSIS

Page 1: ...Installation Operating Manual SMART REVERSE OSMOSIS UNIT ...

Page 2: ......

Page 3: ...SPECIFICATIONS 1 1 3 INSTALLATION 3 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted 4 OPERATION 6 5 MAINTENANCE 6 6 TROUBLE SHOOTING 8 2 WARNINGS SYMBOLS 2 7 TERMS OF WARRANTY 9 ...

Page 4: ...s design for installation within minimal space Two outlet options RO water and pre treated water Operating Parameters Chlorine level 0 2ppm TDS 250ppm Water 0 Temperature 5 45 C TECHNICAL SPECIFICATIONS Feed Water Quality Municipal tap water Voltage and Frequency 100 240V 50 60Hz PowerInput 96W Purified Water Flow 1 2L Min Congratulations on selecting a Dayliff Smart Reverse Osmosis They are manuf...

Page 5: ...ess Flow Diagram Technological Process Feed Water T33 Filter RO Filter Special Pump Drain Water Sewer Pipe Goose Faucet DC24V DC24V Indicator Light Main Control Panel Inlet Water Solenoid Water RO Water PP Filter GAC Filter CTO Filter Puri ed Water Optional Diagram Flush Water Solenoid Water Pump Leakage Detector Low Pressure Switch High Pressure Switch ...

Page 6: ... turn off the feed water ball valve and cut off the source water to avoid the water hammer phenomenon which may lead to leakage or damage to housings and lters if go out in daytime or after the last use at night WARNING Please cut off power and source water at once in case troubles occur and ask professional staff to repair WARNING Please pull the power plug and cut off the feed water valve if lon...

Page 7: ...is a pressure surge or wave caused when water in motion is forced to step or change direction suddenly When resident in building close his valve suddenly a pressure wave propagates in the pipeline of building NOTE Main Body Six Filter Cartridges Includes faucet 3 way ball valve three pipes instruction book adapter and drain clamp One Accessory Box Goose Faucet 3 way Ball Valve 3 pipes red blue whi...

Page 8: ...nlet water pipe 3 8 white pipe RO water pipe 1 4 blue pipe Drain water pipe 1 4 red pipe Installation Ball Valve and Tee Fittings Ÿ Install Tee Fitting and 3 way ball Valve as per diagram Ÿ Wrap threads of 3 way ball Valve and Tee Fitting with Teflon tape Ÿ Connect inlet water pipe 3 8 white from unit to Feed Water Valve Ÿ Install 3 way ball valve to Tee fitting and then connect to source water ...

Page 9: ...e bottom of faucet and connect tubing to unit Installation for Drain Clamp Ÿ Place drain clamp on drain pipe above the drain trap and tighten securely Ÿ Using the drain clamp as a guide drill a 6mm hole enough for the 1 4 tubing to pass through one side of the drain pipe DO NOT drill through both sides Ÿ Connect Drain tubing 1 4 red from unit to Drain Clamp Drain Tubing Compression Nut Insert Drai...

Page 10: ...ly system is in standby mode and indicator light keeps in blue when water tank is full 3 Machine stops making water and indicator light keeps in red buzzer rings 30 times after being working continuously for 6 hours or water leakage is detected Cartridges Replacement and Reminder Recommended Replacement Period for Cartridges Cartridges Replacement Please cut off the water turn off the power open R...

Page 11: ...1 Push side board according to arrow direction 2 Lift up cartridge 30 rotate anticlockwise then remove it 3 Install new cartridge by rotating clockwise according to specifications then fix the side board ...

Page 12: ...er and repair water pump Replace high pressure switch Replace RO membrane RO membrane is blocked Water pump pressure loss Water pump works but system does not work Repair water pump Flush solenoid valve is damaged Replace flush solenoid valve Constantly running water in downtime Inlet water solenoid valve damaged Replace inlet water solenoid valve Cannot stop working when pressure tank is full or ...

Page 13: ...or liability implied by law the liability of Dayliff in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair at the Company s discretion defects which under proper use appear therein and arise solely from faulty design materials or workmanship within a specified period This period commences immediately after the equipment has been delivered to t...

Page 14: ......

Page 15: ......

Page 16: ...INS463A 09 20 www davisandshirtliff com ...