2
A thermal cut-out is provided in the motor winding to protect against pump overload
and the pump can be connected directly to the mains power supply through a 10A
fuse or MCB.
Enclosure Class:
IP68
Insulation Class:
F
Voltage:
1x240V
OPERATING CONDITIONS
Pumped liquid:
Thin, clean, chemically non-aggressive liquid containing some
particles and fibres.
0
Max fluid temperature:
+35 C
Max Operating Depth:
8m
Pump
Motor
Dimensions (mm)
Weight
(kg)
kW
Amps
W
0.75
5.2
1¼”
220
320
5.0
0.75
5.2
1¼”
250
350
6.0
Outlet
H
DDW 750S
DDW 750V
Pump Data
2. INSTALLATION
!
The pump can be used for various drainage and
water transfer installations for tanks, ponds and
basements. It is best installed in a sump of
minimum 40cm square and 50cm deep to
allow for float switch operation.
!
The pump should not be suspended by its cable
or delivery pipe. It should either rest on a solid,
level base or be suspended by steel cable or
chain.
!
The pump may be connected by either a rigid pipe or hose; diameter should
be no less than the outlet connector.
!
Ensure the pump is not resting in silt or sand during normal operation or
impeller damage will occur.
!
Adjust the low level control switch on its clip to ensure free float movement
and sufficient time between start and stop cycles.
min400
min500