background image

PUMP
Dayliff Aquastrong CIRC 16 

is a highly innovative smart inverter controlled 

water  boosting  pump  suitable  for  various  domestic  applications  including  hot 
water circulation for electric or solar water heaters as well as shower and general 
tap pressure boosting. Particular features include:- 

  • 

Innovative inverter controlled 

Permanent magnet water cooled DC 

motor that features high efficiency and super silent (28dB) operation. 

  • 

Anti-block hydraulic design

 with large water passage and optional 

easy to clean prefilter.

0

  • 

Suitable for all water temperatures

 up to 90  

  • 

Fully automatic operation

 with inbuilt flow switch control.

  • 

Integrated  Design

 

using  non  corroding  materials  including  an 

aluminium housing and engineering plastic hydraulic parts providing for up 
to 30,000 running hours operation. 

  • 

Extremely compact dimensions 

that enables simplified installation in 

confined spaces. 

  • 

Supplied complete 

with connectors, mounting brackets and separate 

inverter/controller unit.

  •

 

2-year guarantee

  • 

Certified

  in  accordance  with  the  EU  Uniform  EN  and  the  German 

Industrial DIN Standards.  

Dayliff Aquastrong CIRC 16

 is an exceptionally advanced product that uses 

state of the art inverter technology to provide the perfect solution to all domestic 
and residential water supply needs.

Insulation:

 F

 

 

 

Power: 

96W, 175-245V, 50HZ/60HZ 

Enclosure Class:

IP57

  

 

Speed: 

10,000rpm

OPERATING CONDITIONS

Pumped Liquid:

 

Thin, clean, chemically non-aggressive liquids without solid 

particles or fibres

0

Max. Ambient Temp: 

50 C

0

Max. Liquid Temp: 

90 C

Max Suction Lift: 

0m (non self-priming)

Start Flow:

 1 l/min

Inlet/Outlet: 

½”

2

Summary of Contents for AQUASTRONG CIRC 16

Page 1: ...AQUASTRONG CIRC 16 Smart Inline Boosting Pumps Installation Operating Manual...

Page 2: ......

Page 3: ...SPECIFICATIONS 1 1 2 WARNINGS SYMBOLS 3 OPERATION 5 8 TROUBLE SHOOTING 6 9 INDEX Davis Shirtliff Ltd 2021 Contents herein are not warranted WARRANTY 7 11 3 INSTALLATION 4 APPLICATION 4 6...

Page 4: ...of this Installation Manual is therefore important though should there be any queries they should be referred to the equipment supplier PUMP HEAD m 3 FLOW RATE m hr 2 4 6 8 20 12 16 14 10 0 3 18 0 6 0...

Page 5: ...ium housing and engineering plastic hydraulic parts providing for up to 30 000 running hours operation Extremely compact dimensions that enables simplified installation in confined spaces Supplied com...

Page 6: ...uld not be installed in either a high point in the system where air can collect or a low point where sediments could build up WARNING Pipes on both sides of the pump should be supported to reduce stra...

Page 7: ...2 Forced Start Button 3 AC Input Plug 4 Waterproof Connector 5 Inlet Connector 6 Operating LED Indicator Light 7 Pump Body 8 Outlet Connector WARNING Non approved replacement parts may not be used WA...

Page 8: ...ler must be installed either horizontally or vertically Angled installations are not allowed 3 Fix the pump into the pump bracket Installation Arrangement 4 Fasten the copper connectors to the outlet...

Page 9: ...ater proof connector connect the controller to the pump and plug to the power supply the pump shall start automatically Plug into power and pump starts to work Waterproof Connector Water Heater Boosti...

Page 10: ...7 Solar Water Heater Boosting Outlet Piping Hot Water Inlet Piping Cold Water Domestic Applications Shower Shower Support Shower Hose WHB Faucet Boosting WC Cistern Boosting Shower Boosting...

Page 11: ...top automatically due to inbuilt flow sensor If the pump does not work due to water flow being lower than 1 0L min pressing the force start button can activate it CIRC 16 will stop automatically after...

Page 12: ...lashes five times None None Replace the controller Replace the motor Rotor damaged Flow sensor damaged No water in the pipeline Air in the pipeline Air in the pipeline Rotor is worn out The flow senso...

Page 13: ...EXPLODED DIAGRAM 10 Rotor impeller assembly Motor shaft Ceramic washer Parts No 1 2 Water flow switch Parts No 3 4...

Page 14: ...y condition or liability implied by law the liability of Dayliff hereafter called the Distributor in respect of any defect or failure of equipment supplied is limited to making good by replacement or...

Page 15: ......

Page 16: ...INSXXXA 00 21...