D206DC QUICK START GUIDE
RETAINING
SCREW (1/8 HEX KEY)
PLUG THE CRIMPER DIRECTLY INTO A 110 VOLT 20
AMP SINGLE PHASE WALL OUTLET.
DO NOT USE AN EXTENSION CORD OR RUN FROM
PORTABLE POWER SOURCES AS LOW VOLTAGE CAN
DAMAGE THE MOTOR.
THE OIL LEVEL IN THE PUMP
SHOULD BE APPROX. 1 1/2 INCHES
BELOW THE FILLER/VENT PLUG.
PLACE THE STANDARD PRESSURE
PLATE, ANY STANDARD DIE SET AND THE
STANDARD COMPRESSION RING IN THE
BASE OF THE CRIMPER IN THE ORDER
SHOWN.
SLIDE THE PUSHER ONTO THE
STUD OF THE HYDRAULIC RAM.
SET THE MICRO-CRIMP
ADJUSTER AT “95” FOR THE D206DC
PRESS AND HOLD THE START SWITCH.
IF THE RAM EXTENDS AND SHUTS OFF THE MOTOR
IN APPROXIMATELY ONE SECOND AFTER THE PUMP
STARTS TO BUILD PRESSURE, (THE SOUND OF THE PUMP
WILL CHANGE) AND THE DIE SET IS FULLY CLOSED, THE
CRIMPER IS CORRECTLY CALIBRATED.
IF THE TIME TO SHUT OFF IS NOT APPROXIMATELY
1 SECOND, THE CRIMPER MUST BE RECALIBRATED. SEE
INSTRUCTIONS.
FOLLOW THESE STEPS BEFORE YOU USE YOUR
CRIMPER FOR THE FIRST TIME
CALIBRA
TION CHECK PROCEEDURE