CONTROL-
1500A Single Axis Antenna Controller Chapter 4 Modes Function Description
46
accessible will be the
AutoPol Enable
,
Remote Enable,
and
Expert On
. When the Expert
Access flag is set, access to the other CONFIG mode items can be further restricted by the
value of a controlling Config mode item.
An example will clarify the concept of a controlling CONFIG mode item. Three CONFIG mode
items associated with remote access to the controller are
Remote Enable
,
Comm
Address
,
and
Baud (100s)
. The
Remote
Enable
CONFIG item is the controlling item for the
Communications Port Address and Communications Port Baud Rate items. If the
Remote
Enable
CONFIG mode item has a value of 0 (disabled) then the other two items will not appear
in the list of CONFIG mode items. In the descriptions which follow the controlling items and
the items that are controlled by other items will be clearly delineated.
4.9.1 AutoPol
The AutoPol system allows the controller's polarization control function to be slaved to the level
of a digital input derived from a satellite receiver. Please refer to sections 2.6 and 3.8 for more
information on the AutoPol system.
The AutoPol system is disabled and enabled via the
AutoPol Enable
CONFIG mode item.
POS
POL
SS
AUTOPOL ENABLE:0
0-NO, 1-yes CFG
MODE
The
AutoPol Vlevel
CONFIG mode item specifies the polarity of the AutoPol digital input
signal. A value of zero implies that a low on the AutoPol digital input specifies vertical
polarization and a value of one implies that a high level on the AutoPol input selects vertical
polarization. Access to this item is only allowed when the Expert Access Flag is set.
POS
POL
SS
AUTOPOL LEVEL:1
0-lo, 1-HI CFG
MODE
4.9.2 Remote Communication Parameters
The following items are used to enable and configure the remote RS-422 communications
capability. Access to these parameters is allowed only when the Expert Access flag is set.
The
Remote Enable
item is the controlling item for the
Comm Address
and
Baud (100s)
items.
The
Remote Enable
item is used to enable access to REMOTE mode. If REMOTE mode is
enabled, the controller will respond to serial commands whose address matches the
controller's address. If a valid command is received via the communications port, the control
will transfer to REMOTE mode. See Appendices D and E for additional information on the
controller’s remote control characteristics.
DAWNco • 3340 S. Lapeer Rd • Orion, MI 48359-1320 • Ph (248) 391-9200 • Fax (248) 391-9207 • [email protected]