DV-332 Analog/Digital User Guide
49
6. Setting up digital trunk port
6.1 Clock configuration
When digital ports are physically connected to PSTN lines or PBX, you will see the SYNC and ALM
LED turned on. After being synchronized, the ALM LED will be turned off. Therefore, you should only
see the SYNC LED turned on. You can set up clock source in /CONFIG/COMMON.
GW/CONFIG/COMMON>
show
©
==========================================================================
Common Configurations
==========================================================================
yes/no prompt mode (prompt) : YES
watchdog timer (wdt) : YES
# Processing Mode (dtp) : END_OF_DIGIT
web mode (web) : YES
telnet mode (telnet) : YES
telnet keepalive timer (keep) : 0 (sec)
local call feature mode (va) : YES(pickup number : *0)
ethernet wan speed type (wan) : AUTO
ethernet lan speed type (lan) : AUTO
telnet port (tport) : 6000
web port (wport) : 8000
digitmap mode (digitmode): YES
UPS mode (upsmode) : NO
primary clock source (clkp) : NORMAL0(slave0)
long/short haul transceiver (haul) : LONGHAUL
dtu block mode when wan link down (wblmode) : LOGICAL
dtu block when dtu link down (dblchk) : NO
dtu relay control (drelay) : OFF
pcm_coding_law (pcm) : PCM_ALAW
Company name (com) : DAVOLINK
==========================================================================
GW/CONFIG/COMMON>
In order to synchronize clock source, one should be Master and the other one should be Slave. You
have 3 options as follows. Default value is NORMAL0.
FREERUN : Using the clock of GW itself in synchronization. (Master)