Repeater Maintenance
Use the following maintenance routine on a regular basis to prolong the life of all
repeaters in your network.
• Replace batteries on a routine basis based on the number of transmitters
communicating with a single repeater. See the Battery Life Expectancy table in
Appendix A for more information. Also, use the console to determine when to change
• Use a damp cloth to clean the solar power cell window and all surfaces of the repeater
box when replacing the battery.
• Open the repeater enclosure and remove any debris or buildup inside.
• Keep the repeater enclosure closed when not using it to avoid damaging the
components.