AIR TURQUOISE SA | Rte du Pré-au-Comte 8 | CH-1844 Villeneuve | +41 (0)21 965 65 65
Test laboratory for paragliders, paraglider harnesses and paraglider reserve parachutes
Line and Riser Measurements of flight test Paraglider
(1)
Report No. :
Sample name:
Date measure:
Place:
Manufacturer:
S/N:
Responsible:
Linked:
Total line length including risers [mm]
Main brake line with diff color than A,B,C main line? Yes
+strap
Manu
(2)
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Manu
Sample
Diff
Sample
Center
1
6792
6804
12
6733
6728
-5
6781
6779
-2
6866
6871
5
6084
6083
-1
6947
6933
-14
2
6751
6760
9
6683
6676
-7
6692
6690
-3
6777
6782
5
6124
6134
10
6754
6747
-7
3
6806
6815
9
6729
6725
-5
6709
6705
-5
6784
6790
6
6640
6633
-7
4
6760
6765
5
6678
6672
-6
6672
6668
-4
6745
6753
8
6598
6587
-11
5
6756
6761
5
6669
6667
-2
6694
6692
-2
6763
6768
5
6486
6478
-8
6
6738
6746
8
6644
6646
2
6636
6630
-6
6696
6703
7
6386
6381
-5
7
6726
6734
8
6632
6633
1
6606
6602
-4
6662
6667
5
6364
6357
-7
8
6704
6712
8
6613
6611
-2
6590
6582
-9
6643
6649
6
6434
6428
-7
9
6680
6690
10
6593
6592
-1
6591
6583
-9
6640
6645
5
6281
6272
-9
10
6658
6657
-1
6564
6563
-1
6566
6553
-13
6607
6606
-1
6192
6190
-2
11
6607
6608
1
6521
6524
3
6512
6500
-12
6552
6553
1
Stab line to riser:
6102
6088
-14
12
6479
6471
-8
6415
6418
3
6425
6419
-6
6467
6471
4
B
13
6396
6391
-5
6337
6341
4
6370
6366
-4
6407
6415
8
Wing
14
6174
6182
8
6200
6203
3
tip
15
Number Cell:
38
16
Weight of the glider [kg]:
4.26
17
18
Tolerance [mm]
(4)
:
±15
Riser measurement - total length (inner edge) [mm]
(3)
Acc system configuration max travel
Test Atmosphere AGL
Risers
Std
Acc
Trim
Risers
Std
Acc
No. of risers
3
Pressure [hPa]
968.5
A
532
435
n/a
A
502
405
Tolerance [mm]
5
Humidity [%]
58
A'
532
435
n/a
A'
502
405
Temperature [°C]
21.6
B
525
460
n/a
B
495
430
Carabiner [mm]
30
C
516
516
n/a
C
486
486
Tolerance [mm]
2
D
n/a
D
Plausibility check :
Acc
97
*[mm]
Acc
97
*[mm]
*Travel range (distance
[mm]
500
500
Trimmer
n/a
[mm]
Trimmer
n/a
[mm]
between A and rear riser)
Another trim configuration
No
[mm]
10000
10003
If yes (description):
Remark:
Instrument validity
date
Laser distance meter
07.09.2023
Uncertainty of instrument [mm]
3
Line measurements system
07.09.2023
Villeneuve
ISO 91.20
A
B
C
D
E
Stab
Brake
PG_1651.2020
Davinci
Point XS / close trimmer
APT-XS11021-RBKW
19.05.2020
Claude Thurnheer
(3)
Risers, Std=Trim speed, Acc=Accelerated, AND if trimmer: Open=trimmer open, Closed=trimmer closed, Trim=measured at this position.
(4)
Tolerance line and riser is +/-15 [mm]
Total
length
(incl.
Carabiner
or
connect)
Total
length
(no cara-
biner or
con-
nect)
Present inspection’s scope only extends to the conformity of a given sample, on a given date and in a given place – as mentioned here above. The validation of this report is given by the signature of the test manager on inspection certificate 71.8.1
(1)
Total length measured from the underside of the glider to the inner edge of the risers with a tenstion of 50 [N]. Measured values do not include the uncertainty/The uncertainty stated is the expanded uncertainty obtained by multiplying the standard uncertainty
by the coverage factor k = 2. The measured values lies within the assigned range of values with a probability of 95%.
(2)
Manu=Values from manufacturer, Sample=Measured by inspector.
RE | rev 17 | 11.10.2019
Page 1 | 1
ISO | 91.24
Summary of Contents for Point XXS