background image

PRODUCT GUARANTEE (NEW ZEALAND)

Steriflo

®

systems, except for lamps, are guaranteed for a period of one year from the date of original

purchase to be free of material or manufacturing defects.  Should any part fail as a result of such defects
within this period, the pressure system will be repaired free of charge.  Additionally, a one year pro-rata,
parts only guarantee commencing from the date of original purchase shall apply only to the lamp.

TERMS AND CONDITIONS

1.

This guarantee applies to all states and territories of Australia and New Zealand only and is subject to
the provisions of the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of
the various Australian states and the Consumers Guarantee Act 1993 (NZ) as applicable.

2.

The guarantee period commences on the date of original purchase of the equipment.  Evidence of
this date of original purchase must be provided when claiming repairs under guarantee.  It is
recommended you retain all receipts in a safe place.

3.

This guarantee covers parts and workshop labour only.  Goods should be forwarded, with proof of
date of original purchase, to an Authorised Davey Service Centre in Australia or Davey Water Products
Limited in New Zealand, freight paid.

4.

The pro-rata lamp guarantee is calculated on a monthly basis, up to 12 months.

5.

This guarantee is subject to due compliance by the original purchaser with all directions and
conditions set out in the Installation and Operating Instructions.  Failure to comply with these
instructions, damage or breakdown caused by fair wear and tear, negligence, misuse, incorrect
installation, chemical or additives in the water, inadequate protection against freezing, rain or other
adverse weather conditions, corrosive or abrasive water, lightning or high voltage spikes or through
unauthorised persons attempting repairs are not covered under guarantee.  The product must only be
connected to the voltage shown on the nameplate.

6.

Without limiting the original purchaser’s entitlements under the Trade Practices Act (Aust.), the Goods
& Consumer Protection Legislation of the various Australian states, or the Consumers Guarantee Act
1993 (NZ), Davey shall not be liable for any loss of profits or any consequential, indirect or special
loss, damage or injury of any kind whatsoever arising directly or indirectly from the product or any
defect.

7.

Where the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of the various
Australian states and the Consumers Guarantee Act 1993 (NZ) does not apply,  Davey shall not be
liable for any loss of profits or any consequential, indirect or special loss, damage or injury of any kind
whatsoever suffered by the purchaser arising directly or indirectly from the product or any defect and
the purchaser shall indemnify Davey against any claim by any other person whatsoever in respect of
any such loss, damage or injury.

8.

Nothing in this guarantee is intended to have the effect of contracting out of the provisions of the
Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of the various Australian
states and Consumers Guarantee Act 1993 (NZ) except to the extent permitted by the various Acts
and this guarantee is to be modified to the extent necessary to give effect to that intention.

9.

Davey may be collecting personal information from you in order to provide you with a service. Davey
Water Products Pty Ltd promises only to use this information in accordance with the Provisions of the
Privacy Act 1988 (Cth) and the Privacy Policy of Davey Water Products Pty Ltd which is available at
davey.com.au.

® Davey and Steriflo are registered trademarks of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2005.

P/N 400585-3 CC ver 0508 supersedes P/N 400585-2 CC ver 0807

Australia
Davey Water Products Pty Ltd

Member of the GUD Group

ABN 18 066 327 517
Head Office and Manufacturing

Customer Service Centre

Interstate Offices

6 Lakeview Drive,

Ph:

1300 367 866

Sydney • Brisbane • Adelaide

Scoresby, Australia 3179

Fax:

1300 369 119

Perth • Townsville

Ph:

+61 3 9730 9222

E-mail:

[email protected]

Fax:

+61 3 9753 4100

International Offices

Website: davey.com.au

Germany • New Zealand • USA

New Zealand
Davey Water Products Limited

7 Rockridge Avenue,

PO Box 14-641

Penrose, Auckland 1061, New Zealand

Panmure, Auckland 1741

Ph:

+64 9 570 9135

Fax:

+64 9 527 7654

E-mail:

[email protected]

Website: microlene.co.nz

Summary of Contents for STERIFLO SF1000S mkII

Page 1: ...should the UV Chamber be disassembled unless the internal pressure of the unit has been relieved Failure to observe this warning will expose persons to the possibility of personal injury and may resul...

Page 2: ...Connection Page 5 Electrical Power Surge Protection Page 5 6 Pipe Connections Page 6 Pre treatment drinking water Page 6 Lamp Installation Page 7 Operation Page 7 Maintenance Page 8 9 Water Quality Pa...

Page 3: ...with mounting brackets Before installing your new Steriflo please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Ultra...

Page 4: ...Steriflo system from the weather make sure the site is water proof frost free and has adequate ventilation The unit should be either horizontally mounted with the inlet and outlet facing upwards or v...

Page 5: ...or light mounted on its front panel adjacent to the amber power on LED This light will be illuminated whenever the Steriflo control box senses no lamp current There is also an audible alarm in the eve...

Page 6: ...90o bends of a suitable material are connected to the inlet and outlet of the chamber Larger diameter pipe may be used to minimise resistance to flow but maximum flow rates should not be exceeded as c...

Page 7: ...ansport tube touching the lamp as little as possible Handle the lamp by the ends where possible Wipe with clean cloth and methylated spirits if fingerprints or dirt need removing Slide the lamp into t...

Page 8: ...it clean The sleeve should be cleaned every three months or as required Sleeve removal use care fragile 1 Remove lamp as described 2 Remove drain port cap and empty water from chamber 3 Undo nut at o...

Page 9: ...und and the red LED will light and the alarm contacts will changeover These are able to close a normally open solenoid valve The alarm function can be checked by switching the unit off disconnecting t...

Page 10: ...3N70 2 per sleeve d Lamp Connector All models S114 2 WARNING When servicing or attending your Steriflo always ensure power is switched off and lead unplugged Electrical connections should be serviced...

Page 11: ...hours later Severe exposure sore red eyes sensitive to light painful to keep eyes open SKIN Mild exposure slight reddening tenderness mild sunburn symptoms Severe exposure skin sloughing peeling weep...

Page 12: ...ustralian states or the Consumers Guarantee Act 1993 NZ Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising...