Trouble Shooting continued...

c) UV LAMP OUT, ALARM ON

1. Lamp failed.
2. Poor connection to lamp (check/clean connector/lamp pins).
3. Ballast failed (unlikely).

d) LAMP ON, ALARM ON

1. Faulty circuit board.

e) LAMP OUT, ALARM OFF

1. Loose connection or faulty circuit board, possibly short in lamp circuit.

Part Numbers

a) Lamp (SF2500S has 2 lamps and 2 sleeves)

SF1000/SF2500

GPH840N2/S 

b) Sleeve

SF1000/SF2500

QS880

c) O-rings

All models

S24x3N70 (2 per sleeve)

d) Lamp Connector

All models

S114/2

WARNING: When servicing or attending your Steriflo

®

, always

ensure power  is switched off and lead unplugged. Electrical
connections should be serviced only by qualified persons. If the
electrical supply lead of this system is damaged, it must only be
replaced by qualified personnel.

Care should also be taken when servicing or disassembling the
unit and associated pipework to avoid possible injury from
pressurised water. Unplug power, relieve pressure by opening a
tap on the discharge side of the unit and allow any water in the
unit to cool before attempting to dismantle.

Summary of Contents for STERIFLO SF1000S mkII

Page 1: ...should the UV Chamber be disassembled unless the internal pressure of the unit has been relieved Failure to observe this warning will expose persons to the possibility of personal injury and may resul...

Page 2: ...Connection Page 5 Electrical Power Surge Protection Page 5 6 Pipe Connections Page 6 Pre treatment drinking water Page 6 Lamp Installation Page 7 Operation Page 7 Maintenance Page 8 9 Water Quality Pa...

Page 3: ...with mounting brackets Before installing your new Steriflo please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Ultra...

Page 4: ...Steriflo system from the weather make sure the site is water proof frost free and has adequate ventilation The unit should be either horizontally mounted with the inlet and outlet facing upwards or v...

Page 5: ...or light mounted on its front panel adjacent to the amber power on LED This light will be illuminated whenever the Steriflo control box senses no lamp current There is also an audible alarm in the eve...

Page 6: ...90o bends of a suitable material are connected to the inlet and outlet of the chamber Larger diameter pipe may be used to minimise resistance to flow but maximum flow rates should not be exceeded as c...

Page 7: ...ansport tube touching the lamp as little as possible Handle the lamp by the ends where possible Wipe with clean cloth and methylated spirits if fingerprints or dirt need removing Slide the lamp into t...

Page 8: ...it clean The sleeve should be cleaned every three months or as required Sleeve removal use care fragile 1 Remove lamp as described 2 Remove drain port cap and empty water from chamber 3 Undo nut at o...

Page 9: ...und and the red LED will light and the alarm contacts will changeover These are able to close a normally open solenoid valve The alarm function can be checked by switching the unit off disconnecting t...

Page 10: ...3N70 2 per sleeve d Lamp Connector All models S114 2 WARNING When servicing or attending your Steriflo always ensure power is switched off and lead unplugged Electrical connections should be serviced...

Page 11: ...hours later Severe exposure sore red eyes sensitive to light painful to keep eyes open SKIN Mild exposure slight reddening tenderness mild sunburn symptoms Severe exposure skin sloughing peeling weep...

Page 12: ...ustralian states or the Consumers Guarantee Act 1993 NZ Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising...

Reviews: