Low energy operation
Your ProMaster PM200BT has speed settings from 1,500 - 3,600rpm. The ProMaster PM400BT has speed
settings from 1,050 - 3,100rpm. Speed 1 being the slowest and speed 10 being the fastest.
• Speed 1 provides the lowest speed and therefore the greatest energy efficiency and savings.
Operation
Recommended Speed Setting
Backwashing your media filter
Backwash Speed
Pool Filtration
Speed 1 to 4
Suction pool cleaner operation
Speed 5 to 8
Manually cleaning your pool
Speed 9 to 10
Water Feature operation
Spa Jet operation
In-floor cleaning systems
Solar pool heating
Guidelines for recommended pump operating hours
Typical residential pool turnover rate shall be a single turnover of the full volume of the pool water, within the
daily period that the pump would normally be operating. The table below provides a guide only to the running
times of your pump while in filtration mode in order to achieve the minimum turnover rate:
ProMaster PM200BT
Pool size
(Litres)
Speed Setting (hours)
Speed 1
Speed 5
Speed 10
20,000
3.3
1.7
1.1
30,000
5.0
2.5
1.7
40,000
6.7
3.3
2.2
50,000
8.3
4.2
2.8
60,000
10.0
5.0
3.3
80,000
13.3
6.7
4.4
100,000
16.7
8.3
5.6
ProMaster PM400BT
Pool size
(Litres)
Speed Setting (hours)
Speed 1
Speed 5
Speed 10
20,000
2.4
1.3
0.9
30,000
3.7
2.0
1.4
40,000
4.9
2.7
1.9
50,000
6.1
3.3
2.3
60,000
7.4
4.0
2.8
80,000
9.8
5.3
3.8
100,000
12.3
6.7
4.7
8