1. INSTALLATION OF THE PROMASTER
The ProMaster should be located as close to the water as practicable and mounted on a firm base in a well
drained position, high enough to prevent any flooding. It is the installer/owner’s responsibility to locate the
pump such that the nameplate can be easily read and the ProMaster can be readily accessed for service.
It is recommended that the ProMaster is protected from the weather. Enclosures should be ventilated to
prevent condensation build-up.
Failure to follow these instructions and comply with all applicable codes may cause
serious bodily injury and/or property damage.
This pump requires professional expertise for installation and maintenance. The
installation of this product should be carried out by a person knowledgeable in
swimming pool plumbing requirements and who follows the installation instructions
provided in this manual.
Power connection
IMPORTANT INFORMATION Your ProMaster is double insulated to water circuit. If
equipotential bonding structure is required, then an Equipotential Bonding Point
is provided. (Please refer to your local statutes and/or regulations for AS/NZ 3000
equivalent wiring standards).
CAUTION! In the interest of safety, we advise that all brands and types of pool pumps
must be installed in accordance with AS/NZS 3000, known as the national wiring
rules, or equivalent local standards. All electrical installations must be carried out by
a qualified electrician. Davey recommends that all installations are fitted with earth
leakage, or residual current protection devices. Rated residual operating current not
exceeding 30mA.
WARNING! Ensure that an electrical isolation switch is located with easy access so that
the pump can be switched off in an emergency.
F
NFC C 15-100
GB
BS7671:1992
D
DIN VDE 0100-702
EW EVHS-HD 384-7-702
A
OVE 8001-4-702
H
MSZ 2364-702:1994/MSZ 10-533 1/1990
E
UNE 20460-7-702 1993, REBT ITC-BT-31 2002 M
MSA HD 384-7-702.S2
IRL IS HD 384-7-702
PL
PN-IEC 60364-7-702: 1999
I
CEI 64-8/7
CZ
CSN 33 2000 7-702
LUX 384-7.702 S2
SK
STN 33 2000-7-702
NL
NEN 1010-7.702
SLO SIST HD 384-7-702.S2
The ProMaster is suitable for connection to a nominal 220 – 240 volt 50/60Hz power supply and is equipped
with a flex cord. If a power outlet is not available within 3 metres of the pump, a 3-pin power point in a safe,
dry place may need to be provided by an electrician. Extension cords are unsafe around pools and should be
avoided. If the supply cord of the ProMaster is damaged it must be replaced by Davey, or an approved agent
with genuine Davey spares.
The ProMaster incorporates motor overload detection designed to protect the motor from overheating. If the
motor gets too hot during operation, its operating speed will reduce to bring it within an acceptable operating
temperature and then will speed up to the originally set speed.
To reset the motor, switch the power off for 30 seconds, and then return the power from the mains switch.