Removal of Filter

Should it be necessary to remove the filter, the following procedure should be adopted:-
1. 

Switch off the pump and remove the plug from the power point.

2. 

Open all air bleeds in system.

3. 

Close isolating valves where fitted.

4. 

Remove: 

piping connection to the pump

 

 

 

piping connection to the pool return

 

 

 

piping connection to waste

NOTE:  When making any enquiries about your Davey Filter, be certain to

quote the Model Number from the nameplate on the equipment.

WARNING!  Pump suction is hazardous and can trap and drown or disembowel 

bathers.  Do not block suction.  Do not use or operate swimming pools, spas 

or spa baths if a suction cover is broken, missing or loose. Two suction covers 

and inlets must be provided into every pump to avoid suction entrapment.

Routine Maintenance tasks – to maximise the life of your pool equipment & personal 

safety, use this checklist once a week.  Turn pump off first.

a.  Make sure that any pressure gauges are in working condition and the operating 

pressure is within limits as specified on the product.

b.  Make sure that each suction inlet, and main drain has a cover that is securely attached 

and in safe working condition.

c.  Make sure that all skimmer covers are securely attached and in safe working condition. 

These should be replaced every 3 to 4 years.

d.  Remove any obstructions or debris from the main drain cover.

e.  Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and 

debris at least once a week.

f.  Remove obstructions and combustibles from around the pump motor.

g.  Make sure all wiring connections are clean and that all wiring and electrical equipment 

is in good condition. Damaged wiring must be repaired or replaced by a qualified 

electrician as soon as damage is discovered.

h.  Check water balance and sanitiser levels at your local pool shop.

Small children using the pool or spa must ALWAYS have close adult 

supervision.

DANGER - Hazardous suction.  Do not block water entry into filtration 

system with any part of your body as the pressure can trap hair or body 

parts, causing severe injury or death.  Do not block suction.  Turn off 

pump immediately if someone becomes trapped.

Caution! Do not add chemicals directly to the pool skimmer.  Adding 

undiluted chemicals may damage pump and filter and void warranty.

To avoid explosion and possible severe or fatal injury, filter pressure must 

not exceed 280kPa. Do not test filter with compressed air. Check that all 

clamps and fasteners are in good condition and are firmly secured before 

pressurising system. Never adjust clamps or fasteners while filter is 

pressurised.

WARNING:

Always relieve pressure from system before performing any 

service work.

Summary of Contents for EcoPure DEP2540

Page 1: ...pool plumbing requirements following the installation instructions provided in this manual WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily i...

Page 2: ...level concrete slab or similar base with minimum dimensions of 900mm x 600mm 3 x 2 Do not use sand to level the concrete slab as it may wash away and cause vibration and inefficient performance Allow...

Page 3: ...tiport valve to the pool This prevents water draining from the pool during maintenance FAILURE TO COMPLY WITH THE ABOVE CAUTIONS MAY RESULT IN FILTER DAMAGE NOT COVERED BY THE GUARANTEE Pipe Connectio...

Page 4: ...he water in the valve sight glass becomes clear 4 Stop the pump and position the valve handle to FILTER 5 Start the pump The Filter is now in filtration mode 6 To determine the correct operating condi...

Page 5: ...uld also be operated at all times the pool is in use and for about one hour afterwards During the winter the running time may be reduced 4 When the pressure gauge reading is 40 50kPa higher than the c...

Page 6: ...ter backwashing Check for blocked or plugged lines which could restrict flow Large quantities of media returning to the pool One of the lower laterals may be damaged To correct this condition the medi...

Page 7: ...working condition These should be replaced every 3 to 4 years d Remove any obstructions or debris from the main drain cover e Ensure the skimmer baskets and the pump hair and lint pots are free of le...

Page 8: ...The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the...