3. Installation Recommendations
3.1 Recommendations
• Install the pump in a dry place and well away from sources of heat
and in environments not exceeding 45°C. The operating minimum
temperature depends on the liquid to be pumped, bearing in mind that it
must always remain in a liquid state
• Carefully observe any standards in force in your state, territory or
country, as to electrical installation regulations and requirements
• The Davey AS Series pump will be in operation only when your filtration
pump is running
WARNING
• It is important to keep a minimum distance of 200mm
between the probe “C“ and the injection valve “E”
• The injection valve “E” must be placed last in the pipework
hydraulic installation
• In the case of an installation with redox and pH regulation,
it is advised to put the two sensors side by side and the
pH injection before chlorine injection to minimise the risk of
scale deposition on the chlorine injection
• For optimal service life of your peristaltic pump tube, it is
advised not to exceed a pressure of 1 bar and under no
circumstances exceed a pressure of 1.5 bar
• The pH probe must be located before any other device
such as a heater or an electrolyser
Please refer to the enclosed Davey ChloroMatic or Sanitiser
Installation & Operating Instructions for the “Injection Valve”
and “pH probe” location and positioning.