3

NOTE:  The Torrium2

®

 controller fitted to this pump is adaptive.  If your 

pump draws air or is subject to blockage, the Torrium2 adapts to its new 
maximum pressure.  This may result in your system pressure not dropping 
below the new cut-in pressure and your pump not starting.  Should this 
occur, re-prime your pump units as detailed above.  Should this not prove 
successful, it is likely you have a blockage in the pump.  You should 
contact your Davey dealer for assistance.

Rotary Coupling Inlet
1” Male

Horizontal Outlet
1” Male

Priming Cap which covers the 1” Male Vertical Outlet 
and access to the internal check valve.

Status Indicator
Lights

Prime Button

Pressure
Indicator
Window

Fitting the Torrium2

®

 directly to the Pump

The Torrium2

®

 is fitted with a rotary coupling. This 

coupling allows the pump controller to be fitted 
simply and easily to the pump discharge.

The coupling has an oring seal. The controller 
adaptor nut is able to rotate independent of the 
Torrium2

®

 and the complete pump, this allows it 

to be tightened onto the pump easily. For ease 
of installation a tightening tool is included with 
Torrium2

®

 to tighten the controller nut to ensure a 

firm connection to your controller.

The ability to rotate the adaptor nut also means that the complete controller, once 
fitted to the pump, can be rotated a full 360

o

 in the horizontal plane, without causing 

the coupling to unscrew from the pump outlet.

With Torrium2

®

 you can connect the discharge pipework to the 

discharge port and/or the vertical priming port. The priming port is 
able to be used as a discharge port.

WARNING: When servicing or attending pump, always ensure power  
is switched off and lead unplugged. Electrical connections should be 
serviced only by qualified persons. If the electrical supply lead of this 
pressure system is damaged, it must be replaced.

After Sales Service

For professional after sales service or repair contact your Davey Dealer.  For 

assistance in locating your nearest dealer contact the Davey Customer Service 

Centre on 1300 2 DAVEY (1300 232 839) or the appropriate branch as listed on the 

back of this document.

NOTE:
a)  For protection, the Davey

®

 pump motor is fitted with an automatic 

“over temperature” cut-out. Constant tripping of this overload device 
indicates a problem e.g. low voltage at pump, excessive ambient 
temperature (above 50°C) in pump enclosure.

b)  The Torrium2

®

 control device may have to be reset after rectifying any 

of the above operating troubles. This is done by pushing in the “prime” 
button and releasing it after 2 seconds, or switching the power supply 
off then on.

Care should also be taken when servicing or disassembling pump to avoid 
possible injury from pressurised water.  Unplug pump, relieve pressure by 
opening a tap on the discharge side of the pump and allow any hot water in 
the pump to cool before attempting to dismantle.

During servicing, use only approved, non-petrochemical based oring and 
gasket lubrication. If unsure, consult your Davey Dealer for advice.

WARNING: Do not use hydrocarbon based or hydrocarbon propelled 
sprays around the electrical components of this pump.

In accordance with AS/NZS 60335.2.41 we are obliged to inform you that 
this pump is not to be used by children or infirm persons and must not be 
used as a toy by children.

NOTE:  The Torrium2

®

 controller is adaptive.  If your pump draws air or is subject to 

blockage, the Torrium2

®

 adapts to its new maximum pressure.  This may result in 

your system pressure not dropping below the new cut-in pressure and your pump 
not starting.  This is more likely to occur when boosting mains pressure. Should this 
occur, re-prime your pump unit.  Should this not prove successful, it is likely you have 
a blockage in the pump.  You should contact your Davey dealer for assistance.