Auto-retry and Water Return Modes

Should your Torrium2

®

 detect a loss of prime, after stopping the pump, it will wait 

five minutes before activating Auto-retry and Water Return modes.  Auto-retry 

automatically starts the pump to see if the pump is now primed.  It does this after 5 

mins, 30 mins, 1 hr, 2 hrs, 8 hrs, 16 hrs and 32 hrs.  Water return mode will restart 

the pump automatically if the Torrium2

®

 detects water flow through it.

Electrical Power Surge Protection

An electrical power surge or spike can travel on the supply lines and cause serious 
damage to your electrical equipment.  The Torrium2

®

 fitted to this pump has a metal 

oxide varistor (MOV) fitted to help protect it’s circuit.  This MOV is a “sacrificial” 
device, meaning that it effectively is gradually damaged every time it takes a surge.  
The MOV is not a lightning arrestor and may not protect the Torrium2

®

 if lightning or 

a very powerful surge hits the pump unit.
If the installation is subject to electrical power surges or lightning we strongly 
recommend the use of suitable additional surge protection devices on ALL electrical 
equipment.

Surge Protector Status Window

To allow you to check the status of the inbuilt MOV in the Torrium2

®

 there is a 

viewing window at the back of the Torrium2

®

 above the power lead entry / exit 

grommet. The MOV is the blue disc shaped component.  Should it be consumed 
due to power spikes it will almost always blacken the viewing port. This will indicate 
a non-warrantable failure.
In accordance with AS/NZS 60335.2.41 we are obliged to inform you that this pump is 
not to be used by children or infirm persons and must not be used as a toy by children.

Pipe Connections

For best performance use P.V.C. or 

polythene pipes at least the same 

diameter as the pump’s inlet and delivery 

outlet openings. Larger diameter pipe 

may be used to minimise resistance to 

flow when pumping longer distances.

NOTE: For protection, the Davey pump motors are fitted with an automatic 
reset thermal overload, constant tripping of this overload indicates a 
problem e.g. low voltage at pump, excessive temperature (above 50°C) in 
pump enclosure.

Power Connection

Connect lead to power supply designated on pump label. Do not use long 
extension leads as they cause substantial voltage drop, poor pump performance 
and may cause motor overload.

The Davey Torrium2

®

 fitted to this pump has status indicator light mounted 

on its front panel. These lights will only work when unit is connected to an 
electrical supply.

The electrical connections and checks must be made by a qualified 
electrician and comply with applicable local standards.

For Automatic Pressure Pumps Installed with a 

Mains Pressure Hot Water System

To protect your system from damage caused by back 

pressure from hot water systems.  You should always 

have installed on the hot water inlet an approved non-

return valve.

Connection of Mains Scheme or Town Water 

Supply to either Suction or Discharge of Pumps & 

Pressure Systems

Most Water Supply Authorities have strict regulations regarding direct connection of 

pumps to mains water supplies. In most cases an isolating tank is required between 

mains supply and pump. Davey also recommend this method. Directly applied 

mains pressure can exceed pump operating pressure and damage pump.

Davey Water Products Pty Ltd can not 

accept responsibility for loss or damage 

resulting from incorrect or unauthorised 

installations.

NOTE: Always ensure hot water 

systems are installed in compliance with 

manufacturers recommendations and in 

accordance with all local regulations.

Priming and Operation

The Torrium2

®

 module fitted to your CT system is provided with a push button 

“Prime” button. This button is used during initial priming of the pump and also acts 
as a reset button if the Torrium2

®

 switches out in pump protection mode.

1.  Remove priming plug and fill 

casing and suction line (on flooded 
suction,  simply open gate valve to 
pump).  When full, replace priming 
plug.

2.  Ensure outlet nearest
 

to pump is open.

3.  Ensure all valves in suction line 

are open.

4.  Switch on power - The 

status indicator light 

will be illuminated 

green and the pump 

will run.  A full flow 

of water should be 

discharged from the 

open tap.

5.  If the pump stops with the tap open 

see troubleshooting checklist.

 

6.  Close the open outlet or tap and 

the pump should stop after a few 

seconds (the status indicator light 

should be illuminated red (constant).  

If not, consult the troubleshooting 

checklist.

To Reset if Pump switches out in 

Pump Protection Mode

1.  Make sure pump is primed.

2.  Open tap, push prime button.

3.  Close tap and pump will stop.