background image

pag

. 3

1 INTRODUCTION

1.1 The manual

The user guide is the document that accompanies the valve from the time of its construction and throughout the period of 

use, it is therefore an integral part of the valve. It requires reading the manual before taking any action involving the valve. The 

manual must be readily available for use by staff and maintenance of the valve. The user and the attendant use are required 

to know the contents of this manual. 

Reproduction of any part of this manual, in any form, without the express written permission of DAV Tech. The text and 

illustrations in this manual are not binding, the DAV tech reserves the right, at any time and without notice, the right to make 

any changes to improve the product or for reasons of character manufacturing or commercial.

1.2 Warranty

The warranty is valid for a period of 12 months from the date of commissioning and no later than 15 months from the 

date delivery. The interventions carried out during the warranty period does not extend in any way the validity period of the 

guarantee. The seller is not liable for defects caused by normal wear of parts which by their nature are subject to wear.

1.3 Goods receiving

The original configuration of the valve must never be changed.

Upon receipt of the goods, check that:

• The packaging is intact 

• The exact correspondence of the material ordered.

2 TECHNICAL DESCRIPTION

2.1 Valve operation

The DAV 150 volumetric dispensing valve is a pneumatically operated component designed for precision dispensing of low 

viscosity lubricants.

The exchange of the pneumatic supply, at a pressure equal to or greater than 6 bar, will lead to the emptying of the volumetric 

chamber and the relative outflow of a constant and adjustable quantity of fluid.

2.2 Technical specification

Model

DAV 150

Configuration

Standard (assembly block)

Dispensing range [mm³]

3-200

Dispensing range [ml]

0,003-0,200

Weight [kg]

0,78

Connection (medium intake) inside thread

G 1/8”

Connection (medium discharge/pressure discharge) inside thread

G 1/8”

Optimal medium intake working pressure [bar]

1-6

Max. medium intake working pressure [bar]

12

Connection (compressed air) inside thread

M5 for hose ø4 mm

Bleed hose connection

ø 4 mm

Min./max. pneumatic operating pressure [bar]

5/7

Optimal pneumatic operating pressure [bar]

6

Compressed air quality

ISO 8573-1:2020 [6:4:4]

VOLUMETRIC DISPENSING VALVE DAV 150

Summary of Contents for DAV 150

Page 1: ...ETRIC DISPENSING VALVE DAV 150 DAV TECH SRL Via Ravizza 30 36075 Montecchio Maggiore VI ITALIA Tel 0039 0444 574510 Fax 0039 0444 574324 davtech davtech it www davtech it Installation and maintenance...

Page 2: ...merce 2 DESCRIZIONE TECNICA pag 3 2 1 FunzionI delle valvole 2 2 Specifiche tecniche 3 AVVERTENZE pag 4 4 FORMAZIONE DEL PERSONALE pag 8 5 RILEVAZIONE DI ERRORI ED ELIMINAZIONE DEI GUASTI pag 8 6 MAN...

Page 3: ...defects caused by normal wear of parts which by their nature are subject to wear 1 3 Goods receiving The original configuration of the valve must never be changed Upon receipt of the goods check that...

Page 4: ...ed and the prescribed maintenance and repair work is carried out Fundamental safety instructions The following must be observed for the safe handling and trouble free operation of this product Using t...

Page 5: ...ther than qualified personnel Improper transportation storage assembly commissioning operation and maintenance of the product Failure to observe the information in the operating manual regarding safet...

Page 6: ...o 5 A locking screw Figure A No 4 is provided to retain the set quantity The vent with hose connection Figure B No 7 permits the clean discharge of the medium Description of the pictured components Fi...

Page 7: ...the lubricant viscosity does not change Depending on the application case the control air pressure has to be adjusted to the switching frequency that is used on the one hand and the higher or lower m...

Page 8: ...F PERSONNEL Only trained and instructed personnel who have read and understood all points in the operating instructions may work on the product The personnel must also be able to control the operating...

Page 9: ...al pressure is permitted to remain in the system The medium must be removed and properly disposed of Publisher s copyright The duplication translation or dissemination to third parties of this documen...

Page 10: ...7 BREAKDOWN 28 39 37 30 38 40 47 27 35 10 33 36 19 21 20 13 29 20 14 46 9 49 3 1 4 5 6 7 8 2 45 16 23 43 24 42 41 44 17 25 32 23 18 34 26 22 15 11 12 48 12 31 11 Installation and maintenance guide...

Page 11: ...all 24 009349 1 Compression spring 25 007777 1 Compression spring 26 002213 2 Slot nut 27 634200 2 Connection pneumatic 28 411000 1 Cap nut 29 0001226 1 Socket head screw 30 8512700 1 Set screw 31 001...

Page 12: ...ted machinery the machinery fulfils all relevant provisions of the following EU Directives 2006 42 CE 2006 42 EG 95 16 EG The manufacturer or his authorised representative undertakes to transmit in re...