UNIVERSAL INTERFACE
The universal interface will connect directly to the M425
Torque Transducer. It supplies 12Vdc to power the Transducer
and converts the torque and RPM signal into the outputs
you require.
4 analogue outputs as either 4-20mA (4-12-20mA):
+/-10Vdc, +/-5Vdc, 0-10Vdc or 0-5Vdc, for shaft torque,
RPM, Power and Spare
RS485/RS232 serial data
Ethernet
MODBUS
USB Type Mini B
The interface will also accept an input from an external
tachometer sensor, the output from this sensor can be
directly linked into the torque and power data.
USER INTERFACES
The outputs that can be configured are:
Datum data logging software
The Datum data logging and
configuration software provides a wide
range of control functions of the M425
including set-up and configuration
options plus data logging.
GRAPHIC USER
INTERFACE
Datum Electronic’s Universal Interface provides
options for different operating environments.
Datum Electronics can provide the universal interface
package for either control enclosure application or heavy
industrial applications.