Table No 5. Receipt Format And Copies, PLU Range
Contains 1 line with 8 Fields
Field No. Parameter
Range
Note
1.
Symbols per
1
Default (18 symbols per line)
line
2 32 symbols per line (electr. joournal)
2.
Number of text
0 - 3
Default: 1
raws at the end
of receipt
3.
Flag: print Number 0
No; Default: 0
of purchases
1
Yes
4.
Flag: Print Tax
0
No, Default: 0
1
Yes
5.
Flag: Print operator 0
No; Default
name
1
Yes
6.
Flag: separate total 0
No
with blank lines
1
Yes; Default
7.
Number of receipt 0 - 3
Default: 0 Printing is initiated by
copies
pressing
< >
. In restaurant
mode the printing starts automa-
tically. The printing of next copy
continues by pressing any key.
8.
Number of internal 0 - 3
Internal receipts divide PLUs
receipts
by Departments (Supply areas)
They start automatically.
Default: 0
Field 7 is to define the number of the copies of a special receipt containing
only the amount of the receipt and the signature of the customer when paying
with a credit card. Issuing of the exact copy of the receipt is forbidden.
Field 8 is to define the number of receipts for internal use in which sales
are devided by departments (especially used in restaurant mode where
departments could be the suply area of the meal and drinks).