DT1102 (PS)
24
20220202-V0
Power supply
Supply voltage:
DT1102
DT1102 PS
24 VDC ±10%, 1.6 W
230 V AC/DC ±10%, 3.8 VA (2.4 W)
Overvoltage class:
CAT II.
The overcurrent protection in installation:
4 A (B)
Ambient conditions
Operating temperature range:
0-50 °C *
Storage temperature range:
-20 - +70 °C
Relative humidity:
90% (max., non-condensing)
Place of installation:
cabinet
Mounting position:
vertical (horizontal rail position)
* -20 - +50 °C on request
Electromagnetic compatibility (EMC):
In accordance with the standard EN IEC 61326-1
Conducted: Limits
for
Class A equipments EN 55011
Radiated:
Limits for Class A equipments EN 55011
ESD:
4 kV/8 kV contact / air
-B- criteria
BURST:
Analogue input
Main supply input (PS)
Analogue outputs
4 kV (5/50 ns, 5 kHz)
2 kV (5/50 ns, 5 kHz)
1 kV (5/50 ns, 5 kHz)
-A- criteria
-A- criteria
-A- criteria
SURGE:
Analogue input
Main supply input (PS)
Analogue outputs
4 kV
2 kV (line to ground)
1 kV (line to ground)
-B- criteria
-B- criteria
-B- criteria
Conducted RF immunity:
3 Veff
-A- criteria
Conducted RF emission:
1 group, Class B
Radiated RF immunity:
E=10 V/m
-A- criteria
Radiated RF emission:
1 group, Class B
Power failure bypass:
20 ms @ 230 V AC/DC ±10%
-A- criterion
General data
Housing:
TS-35 rail mounting housing
material: polyamide PA6.6
Fireproof class:
V2-V0 / UL94
Connection: pluggable
screw-terminal
Connecting cable:
1.5 mm
2
(max.)
Dimensions:
12.5 x 108 x 114 mm
(width x height x depth)
Mass: 0.15
kg
Ingress Protection (EN 60529):
IP 20
The Manufacturer maintains the right to change technical data.