5.

 

Firmware Update 

Datavideo usually releases new firmware containing new features or reported bug fixes 
from time to time. Customers can either download the TWP-10 firmware as they wish or 
contact their local dealer or reseller for assistance.  

This section outlines the firmware upgrade process which should take 

approximately 10 

minutes to complete

.  

The existing TWP-10 settings should persist through the

 firmware upgrade process, which 

should not be interrupted once started 

as this could result in a non-responsive unit.  

Successful firmware upgrade on TWP-10 requires: 

 

USB drive with LED indicator 

 

Mini-USB to Female Type A USB cable 

 

Latest firmware file 

 

Procedure 

 

Turn OFF the machine power (turn off the switch on the rear panel or unplug the 

power cable) 

 

Move the DIP switch to OFF position (down) 

 

Connect a USB drive with at least an LED indicator to the mini-USB port of the TWP-

10 via the mini-USB to Female Type A USB cable (the USB drive should contain the 

firmware file) 

 

Connect the power 

 

The firmware update is finished as soon as the USB drive indicator turns OFF 

(approximately 20-30 seconds) 

 

Disconnect the power 

 

Unplug the mini-USB to Female Type A USB cable and move the DIP switch to ON 

position (UP) 

 

Turn ON the machine again to check the firmware version.

 

 

 

 

Summary of Contents for TWP-10

Page 1: ...TWP 10 4K VIDEO WALL PROCESSOR 2x2 Instruction Manual...

Page 2: ...Product Services The information offered in this instruction manual is intended as a guide only At all times Datavideo Technologies will try to give correct complete and suitable information However D...

Page 3: ...ailable consult your Datavideo dealer or your local power company 8 Do not allow anything to rest on the power cord Do not locate this unit where the power cord will be walked on rolled over or otherw...

Page 4: ...systems are not covered under warranty Any errors that are caused by unauthorized third party software installations which are not required by our computer systems are not covered under warranty All...

Page 5: ...nserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling...

Page 6: ...progressive HDCP compliant Image parameters and layouts are automatically saved in flash memory of the device and can be recalled for later use Several image parameters and layouts can be saved in com...

Page 7: ...NDBY mode 2 DC Power Jack DC in socket connects the supplied 12V PSU The connection can be secured by screwing the outer fastening ring of the DC In plug to the socket 3 USB Virtual COM Port Connect t...

Page 8: ...6 HDMI Input Connect the HDMI video source to this port 7 DIP Switch ON UP Operation mode OFF DOWN Firmware update mode 8 HDMI Outputs Connect video display devices to the respective HDMI output port...

Page 9: ...1 Set the TWP 10 as the master device 2 Connect an HDMI video source to the HDMI input of the TWP 10 3 Connect all display devices to the respective HDMI outputs of the TWP 10 4 Connect the 12V 2A DC...

Page 10: ...he system connection setup step by step Note Under Microsoft Windows 7 please run as an administrator 4 1 Start the Software Control Program The following dialog window will pop up upon execution of t...

Page 11: ...e If connection is unsuccessful you will see the status as DISCONNECTED II Quick Setting Selection Note Quick Setting Selection is not available when the input resolution is 4K2K 60Hz On this page you...

Page 12: ...Step 1 Check your input resolution and select the appropriate outputresolution Click the TV icon to start configuring the output resolution As you select different output resolutions the output TV scr...

Page 13: ...figuring the output TV resolution position size and split screen The three modes are Quick Selection From file and Custom Settings The details of each mode will be described in Steps 2 1 2 2 and 2 3 s...

Page 14: ...on 4x1 This mode divides the screen into 4 parts and allows screen rotation When 3x1 or 4x1 mode is selected a red circle will appear on the image displayed in the right half of the control interface...

Page 15: ...the screen Horizontal shift Vertical shift You can arbitrarily move the image on the screen in horizontal or vertical direction The image is moved one pixel at atime III EDID Extended Display Identif...

Page 16: ...ect the Output Click button to learn display EDID Load EDID from File Click button to select the EDID file and load it into the designated input View EDID content Select the EDID input source Input Ou...

Page 17: ...Please note the maximum string length is 8 Change Graph You can change the default graph on this machine Click button to select the graph After the graph is loaded please click button to write this g...

Page 18: ...screen position is configurable VI IP Configure You can also configure the device via Ethernet connection 1 Click button to start configuring the network settings 2 Next you can read the network setti...

Page 19: ...ware versions VIII Refresh This function not only refreshes the setting information but also reconnects the TWP 10 Click button to update the connection mode The ReConnectForm dialog window will be po...

Page 20: ...l firmware upgrade on TWP 10 requires USB drive with LED indicator Mini USB to Female Type A USB cable Latest firmware file Procedure Turn OFF the machine power turn off the switch on the rear panel o...

Page 21: ...age will be displayed on the opened UI device power cycle is required to store system functions 5 Flicker noise is seen on the output image after the output resolution is adjusted Please power cycle t...

Page 22: ...22 7 Dimensions Weight All measurements in millimeters mm...

Page 23: ...ort Yes ESD Protection Human body 15kV Air gap discharge 8kV Contact discharge Input Port 1xHDMI 1xUSB 1xRJ 45 Output Port 4xHDMI 1xStereo Control IR Remote Control Ethernet USB Virtual Front Panel In...

Page 24: ...91 0120 2427338 E mail sales datavideo in Tel 91 0120 2427337 A 132 Sec 63 Noida 201307 India India Noida Datavideo India Kochi Tel 91 4844 025336 Fax 91 4844 047696 2nd Floor North Wing Govardhan Bui...

Reviews: