background image

10 

 

 

 

W.BAL switch 

This switch is used to recall the preset or stored values of white balance 
in the camera. 

 

A or B: This will apply the value stored in the white balance A or B 
memory in the camera recorder. When the AWB / ABB switch is set to 
the AWB position, the white balance is automatically adjusted and the 
value adjusted is stored in the selected memory A or B.  

 
PRST 

This will apply the preset value of the white balance stored in the camera 
recorder.  

 
 

 

CAM A.KNEE switch 

To select the video signals to be output from the camera.  

 
BARS 

Camera generated colour bar signals are output.

 

 

 
CAM. AUTO KNEE OFF 

The images shot by camera are output. The AUTO KNEE circuit does 
not work. MANUAL KNEE is set as the camera recorder's initial setting.  

 
CAM. AUTO KNEE ON 

The images shot by the camera are output. The AUTO KNEE circuit 
works.  
 

NOTE:

 AUTO KNEE circuit will not be effective if DRS (Dynamic Range 

Stretch) function is enabled. It is also possible allocate the MANUAL 
KNEE and DRS functions via the menu settings on the camera. 
 
 

 

GAIN switch 

Allows selection of the video amplifier’s gain depending on the lighting 
conditions that are present in the camera’s location. 
 
Moving the switch upwards increases the gain in dB steps. 
Moving the switch downwards decreases the gain in dB steps. 
 
 

 

 
 

Master Pedestal Control 

These buttons are used to adjust the level of the Master Pedestal. 
 
 
 

 

 
 

Enable & Painting Adjustment buttons 

Press the ENABLE button in the 

Painting area

 of the MCU-100S before 

choosing to adjust either the level of the Red and Blue Gain or the RGB 
Pedestal values. 

 

Mini USB 2.0 port 

This port is used for firmware updates or to save/transfer MCU-100S 
settings to computer. 

See 

page 14

 for firmware update details. 

 

Summary of Contents for MCU-100S

Page 1: ......

Page 2: ...that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord rating 10 Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes 11 Never push objects of any kind into this unit through the cabinet ventilation slots as they may touch dangerous voltage points or short out parts that ...

Page 3: ...ter please visit www datavideo com or contact your local Datavideo office or authorized Distributors Certain parts with limited lifetime expectancy such as LCD Panels DVD Drives Hard Drives are only covered for the first 10 000 hours or 1 year whichever comes first Any second year warranty claims must be made to your local Datavideo office or one of its authorized Distributors before the extended ...

Page 4: ...s Four RJ 45 connections allow remote set up of up to four SONY cameras RJ 45 cabling allows unit to be placed up to 300m away from the camera s Control of Record and Playback functions Control of Camera User memory functions Control of Camera OSD Menu Navigation Control of Shutter adjustment Control of Iris adjustment Control of AWB ABB functions Control of White Balance A B and Preset functions ...

Page 5: ...5 Example MCU 100S Set Up ...

Page 6: ...CU 100S Keyboard Cameral Select Memory Store Recorder Control Cancel Menu Write Black Balance USB for F W Update Check LED Display Shutter Selection Gain IRIS Adjustment Power Master Pedestal Control Enable Painting Adjustment CAM ...

Page 7: ...ce 12V DC Input This 9 pin Mini Din can be used for confidence and composition monitoring and in some cases to view the camera s own LCD OSD menus You have to connect CB 40 cable Mini Din 1 to 4 CV out cable to MCU 100P to have this function CB 40 is an optional accessory ...

Page 8: ...e is cued to provide continuity from one shot to the next when this button is pressed while playback is paused PS REW FF those two functions will be updated and had modifications SHORT MARK Press this button during recording or playback to record shot mark 1 ND ND filter select switch and indicator Use this switch to select the ND filter Press the switch upward to change the ND filter in order and...

Page 9: ...e moving the switch to enable the SLS function PS SLS function will be updated and had modifications SEL Select dial The select dial is used for two functions to navigate the menus or to control the shutter speed When the MENU button is active and back lit orange The select dial is turned to navigate through the camera s menu options Pressing in the same dial like a button confirms the current sel...

Page 10: ...N The images shot by the camera are output The AUTO KNEE circuit works NOTE AUTO KNEE circuit will not be effective if DRS Dynamic Range Stretch function is enabled It is also possible allocate the MANUAL KNEE and DRS functions via the menu settings on the camera GAIN switch Allows selection of the video amplifier s gain depending on the lighting conditions that are present in the camera s locatio...

Page 11: ...ter positions can be displayed here by using the CHECK button The M PED PAINTING GAIN R B and BLACK R G B values can also be displayed sequentially here See CHECK button also When in LOCK mode this display will show Lock PS Those LED display functions will be updated and had modifications EXT LED This LED will be ON when a lens extender is detected on the chosen camera PS EXT LED function will be ...

Page 12: ... activated by pressing and holding down the CHECK button for two seconds When in LOCK mode all functions are unavailable except for the 4 Camera selection buttons and the CHECK function This is to prevent unauthorized or unintended operation during a LIVE production The seven segment LED display will also show Lock Iris controls can be quickly accessed in LOCK mode by pressing down on the IRIS Dia...

Page 13: ...ra or connector pins may happen NOTE With the AD 1S connected the menu and other functions of the Sony camera may be limited to remote control only To regain manual control of the menu functions on the camera first disconnect the AD 1S The AD 1S also features a BNC type Composite CV output which can be taken to an SD monitor on or near the camera This Composite output can be used for confidence an...

Page 14: ...t Note It is best to update the firmware of the AD 1S unit s at the same time as the MCU 100S How to update the MCU 100S firmware 1 Turn off the MCU 100S power 2 USB cable connects the MCU 100S to PC 3 Set the five switches on the MCU 100S to their middle position 4 Move switch up towards AWB and at the same time also press the shutter select button in Hold both in place 5 Turn on the MCU 100S pow...

Page 15: ...imensions MCU 100S AD 1S Specifications Power Consumption DC 12V 0 5A 15W MAX Weight 350 g Dimension 95mm W x 208mm H x 65 5mm D Input Output Connection RJ45 x 4 Connection Distance Up to 300m CAT 5 or CAT6 ...

Page 16: ...16 ...

Reviews: