background image

 

- 13 - 

Others

 

Parameter 

Specification 

Limit  Units 

Conditions/Comments 

Phantom Power 

+48V 

±3% 

VDC 

NA 

Power Consumption 

12V/19W 

±3% 

watts 

NA

 

 

Power Input connector 

2pin DC Jack 

NA

 

 

NA

 

 

NA 

Dimensions (Main Unit) 

147 x 440 x 45.4 

±1% 

mm 

L X W X H 

Dimensions (Control Unit) 

90.5 x 440 x 47.5 

±1% 

mm 

L X W X H 

Weight 

Main Unit 1.8kg / Control Unit 1.1kg 

NA 

kg 

NA

 

 

Display 

1,77" OLED 

NA

 

 

NA

 

 

 

160XRGBX128 

Audio Delay for audio input 

0~3 sec 

NA

 

 

NA

 

 

NA

 

 

 

Operating and Storage temperature 

Parameter

 

Specification

 

Operating temperature 

0

˚

C ~ +50

˚

C

 

Storage temperature 

0

˚

C ~ +60

˚

C

 

 

Certification 

CE / FCC

 

 

AD-200 Main Unit 

 

 

AD-200 Control Unit 

 

Summary of Contents for AD-200 Main Unit

Page 1: ...AD 200 AUDIO DELAY BOX WITH LEVEL ADJUSTMENT Instruction manual ...

Page 2: ...correct complete and suitable information However Datavideo Technologies cannot exclude that some information in this manual from time to time may not be correct or may be incomplete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check the information in this document for accuracy before making any purchase decision ...

Page 3: ...te this unit where the power cord will be walked on rolled over or otherwise stressed 9 If an extension cord must be used with this unit make sure that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord rating 10 Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes 11 Neve...

Page 4: ...urchase Certain parts with limited lifetime expectancy such as LCD panels DVD drives Hard Drive Solid State Drive SD Card USB Thumb Drive Lighting Camera module PCIe Card are covered for 1 year The three year warranty must be registered on Datavideo s official website or with your local Datavideo office or one of its authorized distributors within 30 days of purchase Disposal For EU Customers only...

Page 5: ... 5 Connection of AD 200 main unit and AD 200 control unit AD 200 Main Unit AD 200 Control Unit D Sub Cable Connected Cable D SUB CABLE Connected CABLE ...

Page 6: ...t of control unit must be connected to audio output of main unit via a connected cable Grounding Terminal When connecting this unit to any other component make sure that it is properly grounded by connecting this terminal to an appropriate point When connecting use the socket and be sure to use wire with a cross sectional area of at least 1 0 mm2 ...

Page 7: ... input channels You can use ch1 2 audio input for XLR or RCA AUX Audio Input 2 channels of XLR balanced audio input For more information please see page 8 for more details RS 232 REMOTE To be updated USB Firmware Upgrades DC IN Socket Connect the supplied 12V PSU to this socket The power connection can be secured by screwing the outer fastening ring of the DC IN plug to the socket ...

Page 8: ...controls audio input channel CH1 CH6 This row of audio channel selection buttons has built in OLED to show active input channel Level control for each audio input source is done by rotating the knobs above each of the audio channel selection buttons Level ranges from 80dB to 12dB The maximum audio level gain can be configured using the SET GAIN function on OSD menu OLED Panel Audio Meters Function...

Page 9: ... be secured by screwing the outer fastening ring of the DC In plug to the socket Note AD 200 main unit and AD 200 control unit both have DC IN Socket they are the same function you just need select one socket to supply the power input Grounding Terminal When connecting this unit to any other component make sure that it is properly grounded by connecting this terminal to an appropriate point When c...

Page 10: ...the appropriate microphone and read the advice in the manual regarding phantom power as some MICs have internal batteries too On Screen Display Function Menu 1 MIXER I O Configuration The mixer has six input channels which are mixed in different combinations The mixed audio is subsequently sent to the output channel In the example illustrated below the mixer setting is configured by enabling the d...

Page 11: ...box being the least bright Brightest Least Bright TEST Different colours Red Green Blue Black and White are available for testing OLED panel DIM The OLED panel dims after the device is idle for 10 seconds There are four dim levels with four filled square boxes being no dim and one filled square box being the most dim No Dim Most Dim RESET This function resets all settings to factory default 5 SET ...

Page 12: ...urce GAIN knob Signal to noise ratio 80 min dB 1KHz 6dBu THD N 0 01 max 1KHz 0dB Frequency Response 20Hz 20KHz 3 dB NA unbalanced mono audio L R RCA NA NA NA Signal to noise ratio 80 min dB 1KHz 0dB RCA IN THD N 0 01 max 1KHz 0dB RCA IN Impedance 15K 10 Ω NA Audio Output Parameter Specification Limit Units Conditions Comments Connector 1 2 3 4 Group A B 3Pin XLR Male NA NA Pin2 Pin3 Pin1 GND Imped...

Page 13: ... 147 x 440 x 45 4 1 mm L X W X H Dimensions Control Unit 90 5 x 440 x 47 5 1 mm L X W X H Weight Main Unit 1 8kg Control Unit 1 1kg NA kg NA Display 1 77 OLED NA NA 160XRGBX128 Audio Delay for audio input 0 3 sec NA NA NA Operating and Storage temperature Parameter Specification Operating temperature 0 C 50 C Storage temperature 0 C 60 C Certification CE FCC AD 200 Main Unit AD 200 Control Unit ...

Page 14: ... 91 0120 2427338 E mail sales datavideo in Tel 91 0120 2427337 A 132 Sec 63 Noida 201307 India India Noida Datavideo India Kochi Tel 91 4844 025336 Fax 91 4844 047696 2nd Floor North Wing Govardhan Building Opp NCC Group Headquaters Chittoor Road Cochin 682035 India Kochi Datavideo Technologies Europe BV Floridadreef 106 3565 AM Utrecht The Netherlands Tel 31 30 261 96 56 Fax 31 30 261 96 57 E mai...