background image

 

- 3 - 

FCC Compliance Statement 

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 

(1).

 

This device may not cause harmful interference, and  

(2).

 

This device must accept any interference received, including interference that may cause undesired 

operation. 

Warnings and Precautions 

1.

 

Read all of these warnings and save them for later reference. 

2.

 

Follow all warnings and instructions marked on this unit. 

3.

 

Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol 

cleaners. Use a damp cloth for cleaning. 

4.

 

Do not use this unit in or near water.  

5.

 

Do not place this unit on an unstable cart, stand, or table. The unit may fall, causing serious damage. 

6.

 

Slots and openings on the cabinet top, back, and bottom are provided for ventilation. To ensure safe 

and reliable operation of this unit, and to protect it from overheating, do not block or cover these 

openings. Do not place this unit on a bed, sofa, rug, or similar surface, as the ventilation openings on 

the bottom of the cabinet will be blocked. This unit should never be placed near or over a heat register 

or radiator. This unit should not be placed in a built-in installation unless proper ventilation is provided. 

7.

 

This product should only be operated from the type of power source indicated on the marking label of 

the AC adapter. If you are not sure of the type of power available, consult your Datavideo dealer or your 

local power company. 

8.

 

Do not allow anything to rest on the power cord. Do not locate this unit where the power cord will be 

walked on, rolled over, or otherwise stressed. 

9.

 

If an extension cord must be used with this unit, make sure that the total of the ampere ratings on the 

products plugged into the extension cord do not exceed the extension cord rating. 

10.

 

Make sure that the total amperes of all the units that are plugged into a single wall outlet do not 

exceed 15 amperes. 

11.

 

Never push objects of any kind into this unit through the cabinet ventilation slots, as they may touch 

dangerous voltage points or short out parts that could result in risk of fire or electric shock. Never spill 

liquid of any kind onto or into this unit. 

12.

 

Except as specifically explained elsewhere in this manual, do not attempt to service this product 

yourself. Opening or removing covers that are marked “Do Not Remove” may expose you to dangerous 

voltage points or other risks, and will void your warranty. Refer all service issues to qualified service 

personnel. 

13.

 

Unplug this product from the wall outlet and refer to qualified service personnel under the following 

conditions: 

a.

 

When the power cord is damaged or frayed; 

b.

 

When liquid has spilled into the unit; 

c.

 

When the product has been exposed to rain or water;  

d.

 

When the product does not operate normally under normal operating conditions. Adjust only 

those controls that are covered by the operating instructions in this manual; improper 

adjustment of other controls may result in damage to the unit and may often require extensive 

work by a qualified technician to restore the unit to normal operation; 

e.

 

When the product has been dropped or the cabinet has been damaged; 

f.

 

When the product exhibits a distinct change in performance, indicating a need for service.

 

 
 
 
 

Summary of Contents for AD-200 Main Unit

Page 1: ...AD 200 AUDIO DELAY BOX WITH LEVEL ADJUSTMENT Instruction manual ...

Page 2: ...correct complete and suitable information However Datavideo Technologies cannot exclude that some information in this manual from time to time may not be correct or may be incomplete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check the information in this document for accuracy before making any purchase decision ...

Page 3: ...te this unit where the power cord will be walked on rolled over or otherwise stressed 9 If an extension cord must be used with this unit make sure that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord rating 10 Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes 11 Neve...

Page 4: ...urchase Certain parts with limited lifetime expectancy such as LCD panels DVD drives Hard Drive Solid State Drive SD Card USB Thumb Drive Lighting Camera module PCIe Card are covered for 1 year The three year warranty must be registered on Datavideo s official website or with your local Datavideo office or one of its authorized distributors within 30 days of purchase Disposal For EU Customers only...

Page 5: ... 5 Connection of AD 200 main unit and AD 200 control unit AD 200 Main Unit AD 200 Control Unit D Sub Cable Connected Cable D SUB CABLE Connected CABLE ...

Page 6: ...t of control unit must be connected to audio output of main unit via a connected cable Grounding Terminal When connecting this unit to any other component make sure that it is properly grounded by connecting this terminal to an appropriate point When connecting use the socket and be sure to use wire with a cross sectional area of at least 1 0 mm2 ...

Page 7: ... input channels You can use ch1 2 audio input for XLR or RCA AUX Audio Input 2 channels of XLR balanced audio input For more information please see page 8 for more details RS 232 REMOTE To be updated USB Firmware Upgrades DC IN Socket Connect the supplied 12V PSU to this socket The power connection can be secured by screwing the outer fastening ring of the DC IN plug to the socket ...

Page 8: ...controls audio input channel CH1 CH6 This row of audio channel selection buttons has built in OLED to show active input channel Level control for each audio input source is done by rotating the knobs above each of the audio channel selection buttons Level ranges from 80dB to 12dB The maximum audio level gain can be configured using the SET GAIN function on OSD menu OLED Panel Audio Meters Function...

Page 9: ... be secured by screwing the outer fastening ring of the DC In plug to the socket Note AD 200 main unit and AD 200 control unit both have DC IN Socket they are the same function you just need select one socket to supply the power input Grounding Terminal When connecting this unit to any other component make sure that it is properly grounded by connecting this terminal to an appropriate point When c...

Page 10: ...the appropriate microphone and read the advice in the manual regarding phantom power as some MICs have internal batteries too On Screen Display Function Menu 1 MIXER I O Configuration The mixer has six input channels which are mixed in different combinations The mixed audio is subsequently sent to the output channel In the example illustrated below the mixer setting is configured by enabling the d...

Page 11: ...box being the least bright Brightest Least Bright TEST Different colours Red Green Blue Black and White are available for testing OLED panel DIM The OLED panel dims after the device is idle for 10 seconds There are four dim levels with four filled square boxes being no dim and one filled square box being the most dim No Dim Most Dim RESET This function resets all settings to factory default 5 SET ...

Page 12: ...urce GAIN knob Signal to noise ratio 80 min dB 1KHz 6dBu THD N 0 01 max 1KHz 0dB Frequency Response 20Hz 20KHz 3 dB NA unbalanced mono audio L R RCA NA NA NA Signal to noise ratio 80 min dB 1KHz 0dB RCA IN THD N 0 01 max 1KHz 0dB RCA IN Impedance 15K 10 Ω NA Audio Output Parameter Specification Limit Units Conditions Comments Connector 1 2 3 4 Group A B 3Pin XLR Male NA NA Pin2 Pin3 Pin1 GND Imped...

Page 13: ... 147 x 440 x 45 4 1 mm L X W X H Dimensions Control Unit 90 5 x 440 x 47 5 1 mm L X W X H Weight Main Unit 1 8kg Control Unit 1 1kg NA kg NA Display 1 77 OLED NA NA 160XRGBX128 Audio Delay for audio input 0 3 sec NA NA NA Operating and Storage temperature Parameter Specification Operating temperature 0 C 50 C Storage temperature 0 C 60 C Certification CE FCC AD 200 Main Unit AD 200 Control Unit ...

Page 14: ... 91 0120 2427338 E mail sales datavideo in Tel 91 0120 2427337 A 132 Sec 63 Noida 201307 India India Noida Datavideo India Kochi Tel 91 4844 025336 Fax 91 4844 047696 2nd Floor North Wing Govardhan Building Opp NCC Group Headquaters Chittoor Road Cochin 682035 India Kochi Datavideo Technologies Europe BV Floridadreef 106 3565 AM Utrecht The Netherlands Tel 31 30 261 96 56 Fax 31 30 261 96 57 E mai...

Reviews: