6 A L A R M S
The following table reflects new alarm types generated by the
IP-DSU
. Alarms are
visible at the console and via StarKeeper® II NMS.
Alarm Text
Severity
Notes
None
N/A
Cold Start trap alarm generated when the
unit starts up
Tx Error on 10BaseT. Check
Physical Connection.
Major
Problem with 10BaseT physical connection
Lost Connectivity to Peer IP-DSU
Minor
Generated when Peer Connectivity is lost;
DCD & CTS is dropped
Peer Connectivity Established
Info
Generated when Peer Connectivity is
established; DCD & CTS is asserted
User Requested Reboot in Progress
Info
Due to manual reboot
Invalid Login Attempt
Minor
Error in login syntax
Invalid Password Change Attempt
Minor
Use of invalid password
Gateway Connectivity Established
Info
ARP Level Connectivity to Router
ICMP Destination Unreachable Msg
Received
Minor
ICMP Destination Unreachable
None
N/A
Trap alarm for SNMP Authorization Failure
SNMP Trap Manager not reachable
(ICMP)
Info
ICMP Destination unreachable on a Trap