background image

DT-6XXX IP-SPOOL Application User’s Manual – Build 12.0  

 

 

 

04/13/06 

 

 

Datatek Applications Inc. 

19

 

The 

dconn (dc)

 command is used to display all of the current connections into the IP-

SPOOL application. The command does not require any arguments. The report shows the 

connection peer for each active connection. 

8.15 D

ISPLAY 

J

OBS IN 

Q

UEUE 

– 

DQ 

DQUEUE

 

Syntax: dq | dqueue 

The 

dq

 command displays all jobs in the queue assigned to the application instance. 

8.16 

P

URGE 

J

OBS IN 

Q

UEUE 

PURGE

 

Syntax: purge [ queue=<queue name>] [ confirm=yes] 

The 

purge

 command deletes all jobs currently in the queue, where 

<queue name> 

is the 

configured queue name for this instance of the application. The 

queue

 and 

confirm

 

arguments are both required as shown, since the command is destructive and irreversible. 

8.17 D

ISPLAY 

L

OG 

DLOG

 

Syntax: dlog  | dlog clr 

The 

dlog

 command is only visible when the application is logged in. This command is 

used to display the entries in the error log. An exclamation point ( ! )  that precedes a log 

entry denotes new entries.  A double asterisk ( ** ) that precedes a log entry denotes 

folding of multiple similar entries into a single line. The log file can be cleared with the 

command: 

dlog clr 

8.18 

 

D

ISPLAY OF 

M

EASUREMENTS 

DMEAS

 

Syntax: dmeas  

The 

dmeas

 command is only visible when the application is logged in. The command is 

used to display the current measurements on all of the interfaces.  

8.19 C

LEAR 

M

EASUREMENTS 

– 

CLR 

CLEAR

 

Syntax: clr | clear 

The measurements displayed with the 

dmeas

 command are aggregated until cleared. The 

clr

 command will set all measurements to zero. The command has no arguments.   

Summary of Contents for DT-6061

Page 1: ...ON USER S MANUAL FOR DT 6XXX EMBEDDED NETWORK PROCESSORS RELEASE VERSION 12 0 ISSUE 2 379 Campus Drive Suite 100 Somerset NJ 08873 fax 732 667 1091 phone 732 667 1080 email sales datatekcorp com http www datatekcorp com ...

Page 2: ... 16 8 7 Label 16 8 8 OA M Session Timer Configuration timeout 16 8 9 Version ver version 17 8 10 Defining the Shared Printer prt 17 8 11 Verify Configured Options verify vfy 18 8 12 Restoring the Printer Connection rs restore 18 8 13 Removing the Printer Connection rm remove 18 8 14 Displaying Current Connections dc dconn 18 8 15 Display Jobs in Queue dq dqueue 19 8 16 Purge Jobs in Queue purge 19...

Page 3: ...ion User s Manual Build 12 0 04 13 06 Datatek Applications Inc 3 12 3 Software Support 22 12 4 Export Restrictions 22 12 5 Limited Warranty 23 12 6 No Other Warranties 23 12 7 Special Provisions 23 13 Limitation of Liability 23 ...

Page 4: ...lation must include an independent frame ground drop to building ground Refer to User s Manual This symbol is marked on the DT 6XXX adjacent to the ground earth area for the connection of the ground earth conductor This Equipment is to be Installed Only in Restricted Access Areas on Business and Customer Premises Applications in Accordance with Articles 110 16 110 17 and 110 18 of the National Ele...

Page 5: ...y their legacy interfaces Many modern host applications use RFC1179 print spooling to share a common print resource The purpose of the IP SPOOL application is to provide that same functionality to the dedicated printer interfaces of legacy systems The IP SPOOL application has two distinct purposes Allow convenience by providing the ability to route print output to a shared printer anywhere in the ...

Page 6: ...ral Office CODEC Coder Decoder COLO Central Office Co Location DCTU Directly Connected Test Unit DK Datakit IP Internet Protocol LMOS Loop Maintenance Operations System MLT Mechanized Loop Test Operations System NE Network Element OS Operations System OSS Operations Support System RFC Request For Comments Internet Specifications SAM BNS Synchronous Asynchronous Multiplexer SNMP Simple Network Mana...

Page 7: ...cture and command set This includes configuration information hardware specifications and SNMP MIB support DT 6X60 Embedded Network Processor Platform User s Manual Describes the DT 6160 and DT 6260 Embedded Network Processors infrastructure and command set This includes configuration information hardware specifications and SNMP MIB support Universal Mediation Interface UMI Module User s Manual De...

Page 8: ...D E P L O Y M E N T S There are many examples of dedicated printer deployments Consider the following diagram BiSync Host BNS VCS Node B H I M U M I DT 6061 T R K ASCII Printers DT 4000 PCs with 3270 Client Application IP Network TN3270 Application IP B2APRT Application NE NE DT 4000 ASCII Printer Interfaces 10BaseT 10BaseT ...

Page 9: ...rinting applications are independent of each other they have one significant characteristic in common The connection to each print device is dedicated This maintains the legacy interface but precludes sharing a print device by multiple users 1 Throughout this document the reference is to the DT 6160 and DT 4000 For the DT 6160 the DT 6160 and DT 6260 can be used interchangeable The IP SPOOL and ot...

Page 10: ... and initiates connections to an RFC 1179 capable printer which can now be shared with other hosts This is represented in the following diagram In the preceding diagram each of the NE devices now has a connection to a virtual printer which is actually an instance of the IP SPOOL application on the DT 6061 When TN3270 Application IP B2APRT Application IP SPOOL Application BiSync Host BNS VCS Node B...

Page 11: ...ual printer a different IP SPOOL instance This IP SPOOL application instance forwards data to the same shared printer 6 R E D U N D A N C Y R E L I A B I L I T Y The IP SPOOL application takes advantage of the DT 6XXX redundancy infrastructure an optional 1 1 spare arrangement to enhance its reliability Should a DT 6XXX fail the spare immediately takes over automatically and assumes the public IP ...

Page 12: ...iguration and administration of the IP SPOOL application Connections to this TCP port are made via a Telnet client Virtual Printer 1 30000 instance 1 200 Virtual Printer connection is made to this TCP port RFC 1179 Shared Printer 1 Allocated Dynamically The IP SPOOL application will initiate a connection to the shared printer when it has data to print The TCP port used for this connection is alloc...

Page 13: ...orwarded to the shared printer via the RFC1179 protocol assuming the shared printer IP address is defined This is done after the configured capture timeout period has elapsed or when a high water mark in the spooling buffer has been reached After the shared printer acknowledges receiving all data sent to it or a user configurable timeout window has elapsed the connection to the shared printer is d...

Page 14: ...Passwd The login command is used to allow access to the other commands The legal characters for passwords are the upper and lower case letters numbers and the following special characters _ Note that when inputting a password all of these special characters are allowed Double quote is not allowed nor is equal sign allowed as the first character of a password in prompted mode Passwords are case sen...

Page 15: ...ord match the password is changed to the new value 8 4 HELP Syntax help Command The help command is always visible The help command displays the currently allowed commands for the mode that the unit is currently entered An alternative to the help command is a question mark 8 5 BANNER MESSAGE BANNER Syntax banner L System Banner Line default The banner command is only visible when the application i...

Page 16: ...ne may be changed individually Comments may be cleared by setting the line value to a null comment i e 8 7 LABEL Syntax label label string none If the command is issued without arguments the current configuration is displayed When issued with an argument of none the label becomes a NULL label Otherwise a label up to 32 characters is allowed when enclosed in double quotes The double quotes are not ...

Page 17: ...y a TCP port number since that is specified in RFC 1179 The timeout parameter allows the configuration of a hold period of the shared printer after all buffered data has been sent as discussed in sec 7 2 The retry parameter is the number of seconds to wait before attempting a new connection to the shared printer when an attempt fails The range for both timeout and retry is 15 255 seconds The tcppo...

Page 18: ...e The off option will disable the auto remove printer function The range of errors is 1 to 10 8 11 VERIFY CONFIGURED OPTIONS VERIFY VFY Syntax verify vfy The verify vfy command is only visible when the application is logged in The command is used to display the configured options 8 12 RESTORING THE PRINTER CONNECTION RS RESTORE Syntax rs restore prt The rs prt command is only visible when the appl...

Page 19: ... are both required as shown since the command is destructive and irreversible 8 17 DISPLAY LOG DLOG Syntax dlog dlog clr The dlog command is only visible when the application is logged in This command is used to display the entries in the error log An exclamation point that precedes a log entry denotes new entries A double asterisk that precedes a log entry denotes folding of multiple similar entr...

Page 20: ...n counters are only displayed if nonzero The measurements available are as follows Measurement Description Type Number of characters Received on the virtual printer interface Base Number of characters Sent on the virtual printer interface Base Number of characters Received on the Shared Printer interface Base Number of characters Sent on the Shared Printer interface Base Number of successful conne...

Page 21: ...4 34 600 25 34 800 26 35 000 Instance Number of DT 6XXX running IP SPOOL Default IP SPOOL Virtual Printer TCP Port Connect 27 35 200 28 35 400 29 35 600 30 35 800 31 36 000 32 36 200 33 36 400 34 36 600 35 36 800 36 37 000 37 37 200 38 37 400 39 37 600 40 37 800 41 38 000 42 38 200 43 38 400 44 38 600 45 38 800 46 39 000 47 39 200 48 39 400 Note instances 31 through 48 are valid only when using a ...

Page 22: ...r use on more than one HARDWARE The SOFTWARE is licensed with the HARDWARE as a single integrated product The SOFTWARE may only be used with the HARDWARE as set forth in this LICENSE You may not rent lease or lend the SOFTWARE in any manner You may permanently transfer all of your rights under this LICENSE only as part of a permanent sale or transfer of the HARDWARE provided you retain no copies y...

Page 23: ...TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW MANUFACTURER AND ITS SUPPLIERS DISCLAIM ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT WITH REGARD TO THE SOFTWARE AND THE ACCOMPANYING WRITTEN MATERIALS THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY HAVE OTHERS WH...

Page 24: ...a l o n U s er s M a n u a l B u il d 1 2 B u il d 1 2 B u il d 1 2 B u il d 1 2 04 13 06 Datatek Applications Inc 24 Copyright 2003 2006 TeleComp R D Corp Copyright 2001 2002 TeleComp Inc Copyright 2001 2006 Datatek Applications Inc All Rights Reserved Printed in USA Datakit and StarKeeper II NMS are registered trademarks of Lucent Technologies licensed to Datatek Applications Inc a company indep...

Reviews: