background image

 
 

Model K-AB-D25 / M34   Page 3 

MANUAL CONTROL

  

 

A front panel three position switch allows Automatic or Manual Control.  In the AUTO position, the K-AB 
switches on the selected Control Signal.  In the Manual A or B Position, these controls are locked out 
and the relays assume the selected position.

 

 

Status Indication

  

Two front panel LED's indicate switch status. Remote alarms or displays can be controlled by the K-AB 
status signals, form C relay contacts.  Status contacts are connected on the 9 pin (standalone) or 50 pin 
(rack) connectors.  See Appendix A for connector pin assignments. 

 
 

SPECIFICATIONS

  

 

D25 Interface   Three 25 Pin D Subminiature, Female Connectors.  
    23 leads switched.  Pins 1 and 7 are Common 
 
M34 Interface   34 Pin ‘M’ type Winchester Connectors 

19 leads switched:  C,D,E,F,H,J,K,L,P,R,S.T,U,V,W,X,Y,AA,BB. 
Pins A and B are Common. 

 
Indicators   Two Red LEDs indicate Switch status A or B. 
    LED's are driven by extra relay contacts. 
  
Stand Alone Enclosure Height....2.75"       Width.....8.00" 
    Depth.....6.25"       Weight....1.20 lbs. 
    Power Source;  UL Approved Wall Mounted Power 
    Supply.  115 VAC 60 Hz 
 
    External Control and Status Interface; 
    9 pin D Subminiature, Female 
 
Rack Mounted   Standard 19" equipment Cabinet Mount, 8.75" high. 
Card Nest   Model K-AB-R-12 Accepts up to 12 cards per nest. 
    Includes power supply for 115 VAC 60Hz. 
 
    External Relay Controls and Status Contacts 
    Via Two 50 Pin Telco Connectors, Female 
 
Control Circuits  EIA RS-232/V.35, External: 
    Standard EIA RS-232C 
    Maximum Input  + 30 VDC 
 
    TTL, External: 
    Maximum Input +5.5 VDC

 

 
Status Signals     Contacts Form C, 1A @ 30 VDC. Not protected, 
    Use proper external suppression. 

 
 
 