background image

 
 

Model K-AB-D25 / M34   Page 2 

INPUT SELECTION

 

 

The K-AB is designed to be operated by an externally supplied control signal.  The following control 
signals can be used to operate the K-AB.  Install the jumpers as shown to configure the K-AB.

 

 

Control Lead 

Logic Required 

Jumper E1 

Jumper E2  Jumper E3 

Contact 

Close=B Open=A 

Out 

Contact 

LO 

RS-232 

Low=B High=A 

Out 

EIA/TTL 

LO 

RS-232 

High=B Low=A 

Out 

EIA/TTL 

HI 

TTL  

Low=B  High=A 

In 

EIA/TTL 

LO 

 

Gang Switching

 

An additional setting enables the K-AB card to be used in a multi-circuit gang (simultaneous) switching 
arrangement.  When used in this manner, one master card controls one or more slave cards.   Jumper 
E4 sets the master or slave nature of the card.

  

 
No Jumper = Independent   Use any Control Input, as above 
Master =  Card Is Master  Use any Control Input, as above 
Slave =  Card Is Slave   Set for Contact Closure 

 
Only one card in each card nest can be set as Master.  

 

 
 

INSTALLATION AND CONFIGURATION

 

 

Connect External Control Source

 

Standalone models use a nine pin D Subminiature female connector to access the externally supplied 
signals.  Dataprobe supplies a mating connector kit to assist in fabrication of the proper control cable.  
Rack Mounted cards have Control leads terminate on 50 pin Telco connectors on the rear of the          
K-AB-R-12 nest.  See Appendix A for 9 Pin and Telco Connector Pinouts. 
 
The K-AB is often used in conjunction with other Dataprobe remote switch controlling equipment: 

 

Smart-Line:  Multi-Switch Control via Tone dial telephone. 
Call Director:  Dial Line Sharing device with Switch Control capabilities. 
Code Activated Switch:  Multi-Switch Control with ASCII Commands. 
 
Dataprobe can supply interconnect cables for any application

 

 