V130108E
iBoot-G2+
Page 14
7. Web Setup
iBoot-G2+ setup section consists of several pages. Access any page via the buttons on the left of the page.
Each time a setting is changed click on the Save button for that page to save the changes before moving to the
next page.
7.1. Device
Settings
Location ID: Set a 20 Character name to be
displayed on the top of the Home page. This assists
in identifying which iBoot-G2+ is being accessed.
Cycle Time: 0 to 999 seconds power cycle time.
This is the length of time the power will be off during
a reboot, or on during a power burst.
Delay Time: 0 to 999 seconds delay time. When
powering up multiple devices, a delay can be set
between each outlet.
Initial State: Each outlet can be set to the state it will assume when the iBoot-G2+ is powered up or reset
.
The
choices are: On, Off and Last, meaning the state it was in when the power was removed or reset commenced.
Upgrade Enable: Check this box to allow remote firmware upgrades of the iBoot-G2+. When this box is
unchecked, firmware upgrades will not be allowed.
Auto Logout: This setting sets the automatic logout for inactivity on both the web and telnet users. It can be
set from 0 to 99 minutes. 0 disables the Auto Logout feature.
As the iBoot-G2+ allows only one Web user logged in at any time, use caution when disabling the
timeout feature, as it is possible to lock out other users by forgetting to logout. Closing the browser
will not log the user out and will lock out web access. If you do become locked out, access the iBoot-
G2+ via Telnet and reboot the unit, or press the reset button.
7.2. Expansion
Settings
Mode: The iBoot-G2+ has three modes of operation
for the expansion, each with its own set of settings.
Expansion: For use with the iBoot-EXP
expansion units.
Power Control: For use with external switches
to provide manual power control.
Independent I/O: Inputs and outputs are used
without as status and control not associated
with power outlets.
Features are dependent on which mode is selected