background image

 

 

13.  Technical Support and Warranty 

 
Seller  warrants this product, if used  in accordance  with all applicable  instructions, to be free from original  defects in 
material and workmanship for a period of 

Three Years

 from the date of initial purchase.  If the product should prove 

defective within that period, Seller will repair or replace the product, at its sole discretion.  Repairs may be made with 
new or refurbished components and replacements may be new or refurbished at the Sellers sole discretion. Repaired 
or replaced units shall be warrantied for the balance of the original warranty, or 90 days, whichever is greater. 
 

If Purchased from Dataprobe Inc.; 

Service under this Warranty is obtained by shipping the product (with all charges 

prepaid)  to  the  address  below.    Seller  will  pay  return  shipping  charges  within  the  United  States.    Call  Dataprobe 
Technical Service to receive a Return Materials Authorization (RMA) Number prior to sending any equipment back for 
repair.  Include all cables, power supplies, accessories and proof of purchase with shipment. 
 

If purchased from an Authorized Dataprobe Reseller;

 Service under this Warranty is obtained by contacting your 

Authorized Dataprobe Reseller.   
 

THIS  WARRANTY  DOES  NOT  APPLY  TO  NORMAL  WEAR  OR  TO  DAMAGE  RESULTING  FROM  ACCIDENT, 
MISUSE,  ABUSE  OR  NEGLECT.    SELLER  MAKES  NO  EXPRESS  WARRANTIES  OTHER  THAN  THE 
WARRANTY  EXPRESSLY  SET  FORTH  HEREIN.    EXCEPT  TO  THE  EXTENT  PROHIBITED  BY  LAW,  ALL 
IMPLIED  WARRANTIES,  INCLUDING  ALL  WARRANTIES  OF  MERCHANT  ABILITY  OR  FITNESS  FOR  ANY 
PURPOSE  ARE  LIMITED  TO  THE  WARRANTY  PERIOD  SET  FORTH  ABOVE;  AND  THIS  WARRANTY 
EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. 
 

Some  states  do  not  allow  limitations  on  how  long  an  implied  warranty  lasts,  and  some  states  do  not  allow  the 
exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to 
you.    This  warranty  gives  you  specific  legal  rights,  and  you  may  have  other  rights  which  vary  from  jurisdictions  to 
jurisdiction. 
 

WARNING:

 The individual user should take care to determine prior to use whether this device is suitable, adequate or 

safe  for  the  use  intended.    Since  individual  applications  are  subject  to  great  variation,  the  manufacturer  makes  no 
representation or warranty as to the suitability of fitness for any specific application. 
 
 

Dataprobe Inc. 
Technical Support:  201-934-5111 

[email protected]

 

www.dataprobe.com/support.html 

 

Summary of Contents for iBoot-DC

Page 1: ...u the ability to reboot crashed devices with the click of a mouse Be sure to read up on all the features of the iBoot DC Including Web Based setup and control iBoot Cloud Service Control all your iBoots from one web portal AutoPing Automatic monitoring and action for failed equipment Event Scheduling for real time power control Telnet setup and control Management Utility Easy Setup Firmware upgrad...

Page 2: ... and tear Power up alert devices like sirens lamps messages or control environmental system like heaters coolers pumps etc 2 2 Multiple Control Options In addition to the Web control capabilities iBoot DC features several other means to operate automatically or under computer control URL Control You can send a single URL to the iBoot DC containing all the information necessary to query or change t...

Page 3: ...t s 3 2 DC Power Connections iBoot DC uses screw terminal connections for the DC input and switched output connections The screw terminals can be removed to facilitate connection and cable fabrication Maximum Operating Current 5 0 to 29 9 VDC 12 Amps 30 0 to 48 0 VDC 2 Amps The Positive lead is switched When ON the power will be at the NO connection When OFF the power will be at the NC connection ...

Page 4: ...tage is positive RELATIVE to the terminal voltage Do Not connect Chassis Ground when using VDC Power 3 4 Mounting Options iBoot DC is suitable for desktop or shelf mounting A mounting kit for wall and DIN rail mounting is available Order part 1920034 Mounting Kit for iBoot Series Remove all cables from the unit prior to installing or removing any mounting hardware 1920033 Mounting Kit iBoot Series...

Page 5: ...it Do not disassemble the unit 1 Install the Wall Mounting Kit as shown 2 Install the wall mounting ears to the unit using the screws removed in Step 2 2 Install the DIN rail clips using the four screws provided 3 The unit is ready for wall mounting 3 Ready for DIN rail mounting 4 Use M3 or 4 screws not included for attachment to suitable surface ...

Page 6: ... com support iboot dc 2 Run DMUSetup exe 3 Run the DMU Note The IP address can only be set within the first two minutes of powering up the iBoot DC or pressing the reset button see Section 11 The Setup Utility will only work with iBoots on the same physical subnet as the PC Once the DMU is run click on Device Discover to display all the iBoots on your network The DMU will display the Location Name...

Page 7: ...C and click on Manage Launch Browser See Section 6 to configure the iBoot The DMU can also be used to return an iBoot DC to its Factory Default condition This can be used to recover an iBoot DC with a lost password Highlight an iBoot DC from the display and select Set Factory Defaults Using the Utility to reset defaults will not change the network settings allowing you to re access the unit You ca...

Page 8: ...d the Control and Status Page is displayed iBoot DC uses an inactivity timer for security This timeout is user selectable from 0 to 99 minutes Setting to zero disables the timeout feature When there is no activity for the set time in minutes the user is automatically logged out and the username and password will need to be entered again for access This is to prevent accidental lockout by leaving t...

Page 9: ...ded If the iBoot DC is connected to a time server see Section 6 3 The Home page will also show the five most recent history events including the Outlet Action User and Time Date of each event The iBoot DC holds the last 32 events in memory The user can access a complete history webpage download the history in a csv file or clear the history Navigation Menu Refresh Use the Refresh button to obtain ...

Page 10: ...variables is not significant The user and password are not required when Auto Login feature is enabled see Section 6 8 for security options Examples http 192 168 1 254 s 1 u user p user Turn the outlet on for the default user http 192 168 1 254 s 0 t 5 Reboot for 5 seconds with Auto Login http 192 168 1 254 8080 s 2 u admin p admin Return status using http port 8080 URL Command Responses iBoot DC ...

Page 11: ... meaning the state it was in when the power was removed or reset commenced Upgrade Enable Check this box to allow remote firmware upgrades of the iBoot DC When this box is unchecked firmware upgrades will not be allowed Auto Logout This setting sets the automatic logout for inactivity on both the web and telnet users It can be set from 0 to 99 minutes 0 disables the Auto Logout feature As the iBoo...

Page 12: ...able Cloud Services This setting enables the iBoot for iBoot Cloud Services iBCS iBCS allows the iBoot to be monitored and controlled from a web portal from any browser It allows multiple iBoots to be managed from a single portal For a complete description of iBCS and setup instructions see Section 7 Note All of the TCP IP Settings require a reboot of the iBoot DC after clicking Save A Reboot butt...

Page 13: ...Boot DC is installed with the device it monitors and automatically reboots if there is no response Ideal for Kiosks Servers AutoPing as an Alert Generator iBoot DC monitors network device and powers up alarm environmental response or redundant system Ideal for Hot Standby Servers Environmental Control Alert for any Network Failure 6 6 AutoPing Settings Address Enter the IP address of the device or...

Page 14: ...t DC is receiving responses to the ping or that the fail counter has not yet been exceeded If the fail count has been exceeded the status will change to FAIL The Trigger Counter indicates the number of times the AutoPing action has been triggered A counter reset button is provided Note All of the AutoPing Settings require a reboot of the iBoot DC after clicking Save A Reboot button will appear at ...

Page 15: ...the User level operation No login challenge will be required for any mode of operation until any setup function is requested The Admin username and password is required for any admin functions User Disabled There is no User account The Admin username and password will be required for operation and setup functions across all modes of operation This is the factory default mode Two passwords are used...

Page 16: ...ill not allow programming for On Follow Off Latch or Off Latch If a Schedule Settings event has action for Off it will be reprogrammed for On Schedule Settings will not allow programming for action Off Web page will not show the Power OFF button Web Page will not process an HTTP POST for Off URL control will not process an unqualified off status request s 0 A qualified off status request with a ti...

Page 17: ...s device name when on the local network By default the name is iBoot DC xxxx where the xxxx is the last 4 segments of the MAC address for your iBoot DC When you reprogram the name of the device a reboot is required to apply the new name as the LLMNR for the device The LLMNR name does not allow spaces If using the LLMNR feature to access the iBoot DC do not use a space in the name When accessing th...

Page 18: ...igurations 7 1 iBCS Setup Operation Use of the iBoot Cloud Services requires the iBoot to be configured to access the Internet Please review the installation and configuration procedures to insure proper setup a Establish Account with iBoot Cloud Server Visit http iboot co from your browser Click on Register Complete the information Confirm Registration by clicking on the link provided in the emai...

Page 19: ...account Alternatively you can log in to the Service and click on Add Device and enter the activation code in the field provided Congratulations You are now on the cloud e iBCS Main Page The iBCS main web page provides a menu bar with the following options Devices List all registered iBoot units ordered by their Name Click on any iBoot line to manage that unit Locations Group all iBoots by location...

Page 20: ...name the device move the device to a defined location or delete the device Give the device a name and Click Rename Device The remainder of the modal is very similar to the iBoot web page Select Power ON Power OFF or Cycle Power g Assign Names and Locations You can establish multiple locations and assign each iBoot to a location You can also name each iBoot independently from the Device Name that i...

Page 21: ... The maximum auto disconnect time is 8 minutes If the Auto Logout setting is shorter than 8 minutes that setting will apply To avoid this and use a longer auto disconnect time use a telnet client that periodically sends a No Operation NOP command like Dtelnet 8 2 iBoot DC CLI Syntax Command Description Factory Default Control Commands These commands are used to monitor and control the outlet set o...

Page 22: ...92 168 1 254 set subnet dotted decimal This command is used to set the iBoot DC s subnet mask 255 255 255 0 set gateway dotted decimal This command is used to set the Gateway 192 168 1 1 set http port 0 65535 This command sets the port that the iBoot DC s web server listens for incoming connections on When set to 0 the web server is disabled 80 set telnet port 0 65535 This command sets the port th...

Page 23: ...d or Sets single AutoPing or two AutoPing relationship And or Or Single set autoping action none on latch on follow off latch off follow cycle This command is used to set the action that the iBoot DC will perform when the autoping triggers None set autoping cycle 0 999 This command sets the maximum number of power cycles when the AutoPing triggers 0 Unlimited 1 set autoping wait 1 999 This command...

Page 24: ...t 2 00 Server time nist gov set event 1 8 run hold This command is used to all the event to run or put the event on hold run set event 1 8 date mm dd yyyy This command is used to set the scheduled action s start date set event 1 8 time hh mm This command is used to set the time the scheduled action will occur in 24 hour format set event 1 8 action on off cycle This command is used to set the sched...

Page 25: ...ease notes for the upgrade before making changes to you iBoot DC 1 Insure that the Upgrade Enable checkbox is checked in the Network Setup web page of the iBoot DC 2 Run the Device Management Utility available at the link above If the iBoot DC you would like to upgrade is not visible in the list box either Select Device Discover from the menu to locate iBoot DC units on the local network or Select...

Page 26: ...tlet status 10 Seconds push Reset to Factory Defaults Hold the button in until the Outlet LED is blinking then release Hold in while and Power up the iBoot Recovery Mode Allows upload of new firmware to the current IP Address Will recover to the Factory default IP Address 192 168 1 254 if the database has been corrupted Factory reset excluding basic network settings can be done using the Device Ma...

Page 27: ...eptacle Screw Terminals Current Capacity 5 0 29 9 VDC 12 Amps Max 30 0 48VDC 2 Amps Max 12 2 Compliance FCC Part 15 Class B 12 3 Network Dual 10 100 Unshielded Twisted Pair Ethernet Jacks IP Addressed DHCP assigned or Static Internal HTTP Web Server Forms Processing Browser required Telnet Server User Settings Record your Setup here for reference Location HTTP Port MAC Address Auto Ping Address IP...

Page 28: ...er this Warranty is obtained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN EXCEPT TO THE EXTENT PROHIBITED BY LAW ALL IMPLIED WARRANTIES INCLUDING ALL WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR ANY PURPO...