PE Series Operator’s Manual
E-1
Appendix E
Error Codes
The most common error codes transmitted by the Printer are
described below.
Lower case “c”
Printer received a data byte from the host that contains a
framing error (corrupted) due to noise.
Lower case "e"
Memory module won't clear. Retry after a <STX> W
command.
Lower case “v”
Input buffer overflow.
Upper case “I”
This means that an invalid command sequence was sent to
the Printer. The Printer did not understand the command
sequence and terminated the command interpreter.
Upper case “R”
This code will be sent every time the Printer is turned on,
this means there was a hardware reset.
Upper case “T”
This means that the Printer has had a watchdog time-out
condition. This is how a software reset occurs. A software
reset is made by sending the command sequence to the
Printer or by doing a front panel reset.
BELL HEX “07”
This is usually returned on a corrupt image download, or if
you try to load an image that is already installed in the
module.
Summary of Contents for PE
Page 1: ...PE Series Operator s Manual ...
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ...PE Series Operator s Manual 4 ...
Page 31: ...PE Series Operator s Manual 21 ...
Page 37: ...PE Series Operator s Manual 27 ...
Page 51: ...PE Series Operator s Manual 41 ...
Page 57: ...PE Series Operator s Manual 47 ...
Page 72: ......
Page 80: ...PE Series Operator s Manual B 6 ...
Page 81: ...PE Series Operator s Manual B 7 Barcode O ...
Page 82: ...PE Series Operator s Manual B 8 Barcode S Barcode T Barcode z ...
Page 84: ...PE Series Operator s Manual C 2 ...
Page 86: ...PE Series Operator s Manual D 2 ...
Page 88: ...E 2 PE Series Operator s Manual ...
Page 95: ...PE Series Operator s Manual G 1 Appendix G Menu Tree ...
Page 96: ...PE Series Operator s Manual G 2 ...
Page 100: ...PE Series Operator s Manual H 4 ...