Appendix J – General Purpose Input Output Ports
Class Series Programmer’s Manual
231
The
GPIO Port
allows convenient printer to applicator integration. Functions can be configured using the
menu system or via
<STX>Kc
commands. All configuration settings are saved in non-volatile memory.
Jumper settings are critical:
•
Jumper settings allow internal or external power distribution to the applicator circuitry.
•
Jumper settings allow + 5 or +24 VDC output signal levels.
WARNING
Failure to configure the card for the device(s) you are connecting may result in damage to the printer
and/or the applicator.
The table below details the GPIO Port functions, and configurable settings:
Applicator Interface Card GPIO Port (J2) Overview
Pin
#
Signal
Name
Signal
Direction
Active
Setting
Jumper
Placement
Function /
Description
Ground
Ground
JMP 7 ‘On’
Printer chassis ground is used
1
Ground (Configurable)
Open
Open
JMP 7 ‘Off’
Ground return must be supplied
Output
+5 VDC
JMP 8 ‘On’
P5 VDC is used
(.5 amp max.)
2
+5 VDC (Configurable)
Open
Open
JMP 8 ‘Off’
+5 VDC must be supplied
3
Start Of Print
[3]
Input
Programmable
4
Slew Label
Input
Programmable
5
Pause Toggle
Input
Low
6
Reprint
[2]
Input
Low
7
+24 VDC (1.0 amp max.)
Output
+24 VDC
8
Ground
Ground
Ground
N/A
N/A
9
Ribbon Low
Output
Programmable
10
Service Required
[1]
Output
Low
11
End Of Print
Output
Programmable
12
Media Out
Output
Low
13
Ribbon Out
Output
Low
14
Data Ready (DRDY)
Output
Low
JMP 9:
Pins 1 & 2 =
+5 VDC
– OR –
Pins 2 & 3 =
+24 VDC
See the WARNING
message, above.
When inactive, all output pins
will be pulled up to the voltage
determined by this jumper
setting.
15
Spare
Output
N/A
N/A
N/A
[1]
Evoked by occurrences listed under ‘Fault Messages’ in the
A-Class Operator’s Manual
.
[2]
Reprints the last label exactly, with no increment or time stamp changes; use it for error conditions. Always keeping this signal
LOW will result in non-stop printing.
[3]
If active with no current print job,
“WAITING FOR DATA”
is displayed. Specifying a quantity of 9999 while always
keeping this signal ‘ON’ will cause non-stop label printing, except in single label mode (see Imaging Mode, Section 4.2.5 of
the
A-Class Operator’s Manual
), which will cause the printer to stop between labels.
Summary of Contents for Ex2
Page 2: ......
Page 4: ......
Page 15: ...xi Appendix V 281 Bar Code Symbology Information Resources 281 Glossary 283 ...
Page 16: ...xii ...
Page 30: ...Immediate Command Functions 14 Class Series Programmer s Manual ...
Page 52: ...System Level Command Functions 36 Class Series Programmer s Manual ...
Page 144: ...Label Formatting Command Functions 128 Class Series Programmer s Manual ...
Page 162: ...Generating Label Formats 146 Class Series Programmer s Manual ...
Page 182: ...Appendix D Reset Codes 166 Class Series Programmer s Manual ...
Page 192: ...Appendix E Single Byte Symbol Sets 176 Class Series Programmer s Manual ...
Page 236: ...Appendix G Barcode Details 220 Class Series Programmer s Manual ...
Page 242: ...Appendix I Symbol Sets and Character Maps 226 Class Series Programmer s Manual ...
Page 272: ...Appendix P UPC A and EAN 13 256 Class Series Programmer s Manual ...
Page 282: ...Appendix R Plug and Play IDs 266 Class Series Programmer s Manual ...
Page 296: ...Appendix U WiFi Region Country Codes 280 Class Series Programmer s Manual ...
Page 302: ...Glossary 286 Class Series Programmer s Manual ...