17
If...
This means that...
The first red
Indicator light is
illuminated
permanently...
The earth monitor voltage is too high.
Use the earth monitoring feature to
monitor the earth. See
Earth monitoring
on page 9.
The battery symbol
on the LCD is
flashing...
The battery voltage is bad. Check the
battery voltage immediately, using the
battery test setting. See
Testing the
battery voltage
on page 9.
The right arrow on
the LCD is
flashing...
During the first 10 minutes of operation,
the energizer's remote control feature
can be activated. During this period, the
large arrow on the LCD display flashes
to indicate this. This occurs each time
the energizer is switched on when the
energizer's remote control feature has
not been activated This is part of normal
operation.
If...
This means that...
The energizer is not
pulsing and the last
green Indicator light
is flashing...
The energizer has been switched off by a
remote control handset. If you think your
energizer might be being controlled by a
neighbour's remote control handset and
you own a remote control handset
yourself, change your energizer's
address setting (see the remote control
handset's user manual). If you do not
have a remote control handset, take the
energizer to an authorised service centre
to have the remote control feature
disabled.
Servicing
This energizer uses Double Insulation, where two systems of
insulation are provided instead of grounding. No equipment
grounding means is provided in the supply cord of a double-
insulated energizer, nor should a means for equipment
grounding be added to the energizer. Servicing a double-
insulated energizer requires extreme care and knowledge of
the system and should only be done by qualified service
personnel. Replacement parts for a double-insulated
energizer must be identical to the parts they replace. A
double-insulated energizer is marked with the words
DOUBLE INSULATION or DOUBLE INSULATED and/or the
symbol below.