DATAMARS
R-IN 1300 MID User Manual – Rev
3.0
6 (40)
3 O
PERATION WITH
T
ERMINAL
For operation with terminal use any kind of terminal, e.g.
Windows HyperTerminal
with the following
settings:
•
Bits per second
115200
•
Data bits
8
•
Parity
None
•
Stop bits
1
•
Flow control
None
3.1
L
IST OF THE COMMANDS OF THE READER
All commands must be followed by a carriage return (ENTER).
General Commands
Explanation
*d
Detect:
returns the UID-list of all the HF transponders in the field
*i
Interrupts any continuous mode operation (does not disable the
continuous mode)
*x
List of the commands and settings
*v
Firmware Version
*se
Settings:
Displays the current settings (Notice that the settings are maintained
after power off)
*st
Store UIDs
Usage:
with the command
“*st”
switch from the state “Store UIDs
off” to the state “Store UIDs on”. Then start reading with the
command
“*d”
. The detected tags are not sent to the output devices
but are cumulated internally. Using now the command
“*dw”
the
reading process is stopped and the cumulated detected UIDs are
sent to the output devices all at once.
*dw
Download UIDs (this command is coupled with *st – see above)
3.2
G
ENERIC
S
ETTINGS
General settings
Explanation
*rd
Restore default settings
Any previously user defined settings will be deleted and re-
placed by factory defaults.
Confirmation: “Default settings restored”
*co[_]
Continuous mode:
*co0 continuous mode off
*co1 continuous mode on (default)
*in[_]
Number of inventories (for non continuous mode only)
*in[1 .. 9] (default 1 [inventory], example *in5)