DATAMARS
R-IN 1300 MID User Manual – Rev
3.0
18 (40)
4.8
R
EADER
S
ETUP
The “ReaderSetup” tab allows users to specify overall properties of the reader.
It is possible to specify:
the antenna power:
•
0 mW – 4 000 mW
(1000 mW = 1 W; 2000 mW = 2 W; etc. )
the technologies of the transponders being used:
•
ISO-15693
•
I-Code I
the ISO-15693 properties (see corresponding ISO-specification)
•
Request/Response Data Rate
•
Modulation Type/ Modulation Index
•
Quiet Mode /Quiet Storage
•
Time Slots ISO / I-Code-1
The “Lock Code” field specifies a particular behaviour of the reader:
Details for
LockCode 0:
Disabled.
Details for
LockCode 1 (on detection)
: Any transponder is read just once. To read a transponder
again, another one must be read first.
Details for
LockCode 2 (on timeout)
: The transponder is first visible when entering the magnetic
field the first time and it is detected only once without regard to the time spent in the field. A chip
having left the magnetic field can be read again only having spent an amount of time T outside of it. If
the time spent outside the magnetic field is less than T, the chip cannot be detected.
Details for
LockCode 3 (on counter)
: The transponder is visible only once when entering the
magnetic field for the first time. Afterward, to be visible again, it must leave the magnetic field and wait
outside until at least N different transponders have been read (N is the number specified by the field
“Lock Code Count”
).
Note:
LockCode 1
(on detection) is the same as
LockCode 3 (on counter) with N = 1
.
The “Communication” field specifies on which output channels the reader must write the found UIDs.
The “Echo” field specifies whether the
user-input
written onto the terminal (RS-232) must be shown
on the screen or not.
The “Reverse Order” field specifies the representation of the UIDs:
Reverse Order Off :
Uids are not reversed
Reverse Order On :
Uids are reversed