DATAMAN-48PRO2 / DATAMAN-48PRO2C
35
Using LPT port
Switch off PC and programmer. Insert the communication cable included with your
DATAMAN-48PRO2 programmer package to a free printer port on your PC. If your computer
is equipped with only one printer port, substitute the programmer cable for the printer cable.
Connect the opposite cable end to the programmer. Screw on both connectors to counter-
connectors. This is very important. It may be uncomfortable to switch between printer cable
and programmer cable, though it is not recommended to operate the DATAMAN-48PRO2
programmer through a mechanical printer switch. Use of an electronic printer switch is
impossible. But you can install a second multi-I/O in your computer, thus obtaining a
supplementary printer port, says LPT2. So your printer may remain on LPT1 while the
programmer on LPT2.
Switch on the PC.
Connect the connector “8” to a mains plug using attached cable. At this time all 'work result'
LEDs (and 'POWER' LED) light up successive and then switch off. Once the POWER LED
lights with low brightness then the DATAMAN-48PRO2 programmer is ready to run.
Next run the control program for DATAMAN-48PRO2.
Caution!
If you don't want to switch off your PC when connecting the DATAMAN-48PRO2,
proceed as follows
:
When connecting the programmer to the PC: FIRST insert the communications cable
and THEN the power-supply connector.
When disconnecting the programmer from the PC: FIRST disconnect the power-supply
connector and THEN the communication cable.
From DATAMAN-48PRO2 point of view the connecting and disconnecting sequence is
irrelevant. Protection circuits on all programmer inputs keep it safe.
But think of your PC
please
.
Problems related to the DATAMAN-48PRO2 /
DATAMAN-48PRO2C
PC interconnection, and their removing
If you have any problems with DATAMAN-48PRO2 / DATAMAN-48PRO2C
PC
interconnection, see section
Common notes
please.
Manipulation with the programmed device
After selection of desired device for your work, you can insert into the open ZIF socket (the
lever is up) and close socket (the lever is down). The correct orientation of the programmed
device in ZIF socket is shown on the picture near ZIF socket on the programmer's cover. The
programmed device is necessary to insert into the socket also to remove from the socket
when LED BUSY light off.
Note:
Programmer's protection electronics protect the target device and the programmer
itself against either short or long-term power failures and, partly, also against a PC failure.
However, it is not possible to grant the integrity of the target device due to incorrect, user-
selected programming parameters. Target device may be not destroyed by forced interruption
of the control program (reset or switch-off PC), by removing the physical connection to the
programmer, but the content of actually programmed cell may remains undefined. Don't
unplug the target device from the ZIF socket during work with device (LED BUSY shine).
Summary of Contents for Dataman-40Pro
Page 7: ...Quick Start 7 Introduction ...
Page 12: ...12 Quick Start ...
Page 15: ...Detailed description 15 Detailed description ...
Page 16: ...16 DATAMAN 448PRO2 ...
Page 30: ...30 DATAMAN 48PRO2 DATAMAN 48PRO2C ...
Page 45: ...DATAMAN 40PRO 45 DATAMAN 40PRO ...
Page 54: ...54 DATAMAN MEMPRO ...
Page 61: ...Setup 61 Setup ...
Page 72: ...72 PG4UW ...
Page 141: ...PG4UWMC 141 PG4UWMC ...
Page 154: ...154 Installation procedure customized ...
Page 159: ...Common notes 159 Common notes ...
Page 171: ...Troubleshooting and warranty 171 Troubleshooting and warranty ...