152
step 1. Load file (/Loadfile:...)
step 2. Load project (/Prj:...)
step 3. EPROM/FLASH autoselect
step 4. Program device (/Program[:switch])
step 5. Close of control program (/Close only together with parameter /Program)
Example 1:
pg4uwcmd.exe /program:noanyquest /loadfile:c:\empfile.hex
Following operations will perform:
1. start pg4uw.exe (if not already running)
2. load file c:\empfile.hex
3. start program device operation without questions
4. pg4uwcmd.exe is still running and periodically checking status of pg4uw.exe
5. when device programming completes, pg4uwcmd.exe is closed and is returning ExitCode
depending on load file and device programming results in pg4uw.exe. W hen all operations
were successful, pg4uwcmd.exe returns 0, otherwise returns value 1 or more.
Example 2:
pg4uwcmd.exe /program:noanyquest /prj:c:\emproject.eprj
The operations are the same as in Example 1; just Load file operation is replaced by Load
project file c:\emproject.eprj command.
Example 3:
Using pg4uwcmd.exe in batch file and testing return code of pg4uwcmd.exe.
rem ------- beginning of batch -------------------------
@echo off
rem Call application with wished parameters
pg4uwcmd.exe /program:noanyquest /prj:c:\emproject.eprj
rem Detect result of command line execution
rem Variable ErrorLevel is tested, value 1 or greater means the error occurred
if ErrorLevel 1 goto FAILURE
echo Command line operation was successful
goto BATCHEND
:FAILURE
echo Command line operation error(s)
:BATCHEND
echo.
echo This is end of batch file (or continue)
pause
rem ------- end of batch -------------------------
Example 4:
Let's assume the PG4UW control program is running, and has user selected device. We need
to load required data to PG4UW device buffer and save the selected device settings and buffer
content to project file. Data required for device are stored in file c:\15001-25001\file_10.bin.
Project file will be stored at c:\projects\project_10.eprj.
Following command line parameters should be specified to realize wished operation:
pg4uwcmd.exe /loadfile:c:\15001-25001\file_10.bin /saveproject:c:\projects\project_10.eprj
When PG4UW receives the commands, it will do following procedures:
1. loads data file c:\15001-25001\file_10.bin
2. saves the currently selected device settings and buffer data to project file
c:\projects\project_10.eprj
Summary of Contents for 448PRO2AP
Page 6: ...6 Introduction ...
Page 11: ...DATAMAN 448PRO2AP AU 11 DATAMAN 448PRO2AP AU ...
Page 19: ...DATAMAN 448PRO2AP 19 DATAMAN 448PRO2AP ...
Page 26: ...26 DATAMAN 48PRO2AP ...
Page 33: ...Setup 33 Setup ...
Page 38: ...38 Step 8 Installation process will start Step 9 Click Finish button to finish setup ...
Page 56: ...56 PG4UW ...
Page 123: ...PG4UWMC 123 PG4UWMC ...
Page 136: ...136 Installation procedure customized ...
Page 145: ...Common notes 145 Common notes ...
Page 157: ...Troubleshooting and warranty 157 Troubleshooting and warranty ...