TECHNICAL SUPPORT
53
6
SYSTEM
LO
W T
EM
FA
ULT
The environment temperature has
fallen below the minimum
temperature software level. The
value is set at 10°C. The system
turns off the entire power section
(laser diode, Peltier module, RF
driver, etc.) since there is a risk of
damaging the optical parts.
Fans are maintained ON to try to
back to right temperature the
marking system.
Turn off and make sure the
environment temperature complies
with the specifications before you
turn it back on. If it is first installation
wait 30/60 minutes until turn on
again. Read the value displayed in
the System Temp. field in the
SYSTEM MONITOR section,
checking to see if it is near the 10°C
limit. In case the problem re-occurs,
carry out the data log with the
service tool and contact technical
assistance.
S
INT
ERL
OC
DIS
CON
The Aux interlock connector or its
closed contact is not present upon
turning on the system. The entire
internal electronics is disabled.
Turn off and restore the Aux
interlock connector before you
restart the marking system. In case
the problem re-occurs, carry out the
data log with the service tool and
contact technical assistance.
S
SHUT
TE
R
FA
ULT
The internal shutter does not work
properly. Its position is wrong. The
system turns off the entire power
section (laser diode, Peltier module,
RF driver, etc.) since the system may
emit an unwanted laser beam. The
problem may be caused by a
malfunction of the shutter or of its
position sensor, or the internal card
may be malfunctioning.
Turn off, wait 30/60 minutes and
restart. In case the problem re-
occurs, carry out the data log with
the service tool and contact
technical assistance.
DIS
ABLE
SHUT
TE
R
A wrong power on sequence was
carried out. The system was started
with the
Shutter
En
active.
Disable the
Shutter
En
signal and
the system will return to its proper
operating status.
In case the shutter is not disabled,
contact technical assistance.
CAN
CONNE
ERRO
R
The CAN communication between
the internal cards is not working
properly.
The problem may be caused by an
internal connection or a damaged
internal device.
Turn off and restart. In case the
problem re-occurs, carry out the
data log with the service tool and
contact technical assistance.
LOW
VOL
TAG
E
INP
UT
S
The inlet power voltage has fallen
below the minimum voltage software
level. The value is set at 20V DC.
The entire internal electronics is
disabled.
Turn off and restore the power
voltage to 24V DC before you
restart. Read the value displayed in
the
Input Voltage
filed in the
SYSTEM MONI-TOR section,
making sure that the value
displayed is around 24V DC. In
case the problem re-occurs, carry
out the data log with the service tool
and contact technical assistance.